5. PARAMETERS
5 - 24
Control
mode
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
P S T
PB04
FFC
Feed forward
gain
Set the feed forward gain.
When the setting is 100%, the droop pulses during operation at constant speed are
nearly zero. However, sudden acceleration/deceleration will increase the overshoot.
As a guideline, when the feed forward gain setting is 100%, set 1 s or more as the
acceleration time constant up to the rated speed.
Setting range: 0 to 100
0
[%]
Set the load to motor inertia ratio or load to motor mass ratio.
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details. When
the parameter is automatic setting, the value will vary between 0.00 and 100.00.
Setting range: 0.00 to 300.00
7.00
[Multiplier]
PB06
GD2
Load to motor
inertia ratio/
load to motor
mass ratio
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Automatic setting
_ _ _ 1: (Auto tuning mode 1)
_ _ _ 2: (Auto tuning mode 2)
Manual setting
_ _ _ 3 (Manual mode)
_ _ _ 4: (2 gain adjustment mode 2)
PB07
PG1
Model loop
gain
Set the response gain up to the target position.
Increasing the setting value will also increase the response level to the position
command but will be liable to generate vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details.
Setting range: 1.0 to 2000.0
15.0
[rad/s]
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Manual setting
_ _ _ 1: (Auto tuning mode 1)
Automatic setting
_ _ _ 2: (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
Manual setting
_ _ _ 4: (2 gain adjustment mode 2)
PB08
PG2
Position loop
gain
Set the gain of the position loop.
Set this parameter to increase the position response to level load disturbance.
Increasing the setting value will also increase the response level to the load
disturbance but will be liable to generate vibration and/or noise.
The setting of the parameter will be the automatic setting or manual setting
depending on the [Pr. PA08] setting. Refer to the following table for details.
Setting range: 1.0 to 2000.0
37.0
[rad/s]
Pr. PA08
This parameter
_ _ _ 0 (2 gain adjustment mode 1
(interpolation mode))
Automatic setting
_ _ _ 1: (Auto tuning mode 1)
_ _ _ 2: (Auto tuning mode 2)
_ _ _ 3 (Manual mode)
Manual setting
_ _ _ 4: (2 gain adjustment mode 2)
Automatic setting
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......