7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 20
7.2.4 Gain switching procedure
This operation will be described by way of setting examples.
(1) When you choose switching by input device (CDP)
(a) Setting example
Parameter Symbol
Name
Setting
value
Unit
PB06
GD2
Load to motor inertia ratio/load to motor
mass ratio
4.00 [Multiplier]
PB07
PG1
Model loop gain
100
[rad/s]
PB08
PG2
Position loop gain
120
[rad/s]
PB09
VG2
Speed loop gain
3000
[rad/s]
PB10
VIC
Speed integral compensation
20
[ms]
PB19 VRF11
Vibration
suppression control 1 - Vibration
frequency
50 [Hz]
PB20
VRF12 Vibration suppression control 1 -
Resonance frequency
50 [Hz]
PB21 VRF13
Vibration
suppression control 1 - Vibration
frequency damping
0.20
PB22
VRF14 Vibration suppression control 1 -
Resonance frequency damping
0.20
PB52 VRF21
Vibration
suppression control 2 - Vibration
frequency
20 [Hz]
PB53
VRF22 Vibration suppression control 2 -
Resonance frequency
20 [Hz]
PB54 VRF23
Vibration
suppression control 2 - Vibration
frequency damping
0.10
PB55
VRF24 Vibration suppression control 2 -
Resonance frequency damping
0.10
PB29
GD2B
Load to motor inertia ratio/load to motor
mass ratio after gain switching
10.00 [Multiplier]
PB60
PG1B
Model loop gain after gain switching
50
[rad/s]
PB30
PG2B
Position loop gain after gain switching
84
[rad/s]
PB31
VG2B
Speed loop gain after gain switching
4000
[rad/s]
PB32
VICB
Speed integral compensation after gain
switching
50 [ms]
PB26
CDP
Gain switching function
0001
(Switch by input device
(CDP) on/off.)
PB28
CDT
Gain switching time constant
100
[ms]
PB33 VRF11B
Vibration
suppression control 1 - Vibration
frequency after gain switching
60 [Hz]
PB34
VRF12B Vibration suppression control 1 -
Resonance frequency after gain switching
60 [Hz]
PB35 VRF13B
Vibration
suppression control 1 - Vibration
frequency damping after gain switching
0.15
PB36
VRF14B Vibration suppression control 1 -
Resonance frequency damping after gain
switching
0.15
PB56 VRF21B
Vibration
suppression control 2 - Vibration
frequency after gain switching
30 [Hz]
PB57
VRF22B Vibration suppression control 2 -
Resonance frequency after gain switching
30 [Hz]
PB58 VRF23B
Vibration
suppression control 2 - Vibration
frequency damping after gain switching
0.05
PB59
VRF24B Vibration suppression control 2 -
Resonance frequency damping after gain
switching
0.05
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......