11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 7
(2) 400 V class
Regenerative power [W]
Servo amplifier
Built-in
regenerative
resistor
MR-
RB1H-4
[82
Ω
]
(Note 1)
MR-
RB3M-4
[120
Ω
]
(Note 1)
MR-
RB3G-4
[47
Ω
]
(Note 1)
MR-
RB5G-4
[47
Ω
]
(Note 1)
MR-
RB34-4
[26
Ω
]
(Note 1)
MR-
RB54-4
[26
Ω
]
(Note 1)
MR-
RB3U-4
[22
Ω
]
(Note 1)
MR-
RB5U-4
[22
Ω
]
MR-J4-60A4(-RJ)
15
100
300
MR-J4-100A4(-RJ)
15
100
300
MR-J4-200A4(-RJ) 100
300 500
MR-J4-350A4(-RJ) 100
300 500
MR-J4-500A4(-RJ)
130 300
500
MR-J4-700A4(-RJ)
170
300
500
(Note 2) Regenerative power [W]
Servo amplifier
External
regenerative
resistor
(accessory)
MR-RB5K-4
[10
Ω
]
MR-RB6K-4
[10
Ω
]
MR-J4-11KA4(-RJ)
500 (800)
500 (800)
MR-J4-15KA4(-RJ) 850 (1300)
850 (1300)
MR-J4-22KA4(-RJ) 850 (1300)
850 (1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......