11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 14
(3) MR-J4-11KA(-RJ) to MR-J4-22KA(-RJ)/MR-J4-11KA4(-RJ) to MR-J4-22KA4(-RJ) (when using the
supplied regenerative resistor)
CAUTION
Note the followings for supplied regenerative resistors of 11 kW to 22 kW servo
amplifiers because they do not have protect covers.
Touching the resistor will cause a burn because the surface of the parts is a
resistive element and very high temperature.
Even if the power turned off, touching the resistor will cause an electric shock
because the capacitor of the servo amplifier is charged for a while.
When using the regenerative resistors supplied to the servo amplifier, the specified number of resistors
(4 or 5 resistors) must be connected in series. If they are connected in parallel or in less than the
specified number, the servo amplifier may become faulty and/or the regenerative resistors burn.
Install the resistors at intervals of about 70 mm. Cooling the resistors with two cooling fans (1.0 m
3
/min
or more, 92 mm × 92 mm) improves the regeneration capability. In this case, set "_ _ F A" in [Pr. PA02].
P+
C
Servo amplifier
Cooling fan
(Note)
Series connection
5 m or shorter
Note. The number of resistors connected in series depends on the resistor type. The
thermal sensor is not mounted on the attached regenerative resistor. An abnormal
heating of resistor may be generated at a regenerative circuit failure. Install a thermal
sensor near the resistor and establish a protective circuit to shut off the main circuit
power supply when abnormal heating occurs. The detection level of the thermal
sensor varies according to the settings of the resistor. Set the thermal sensor in the
most appropriate position on your design basis, or use the thermal sensor built-in
regenerative option. (MR-RB5R, MR-RB9F, MR-RB9T, MR-RB5K-4, or MR-RB6K-4)
Regenerative power [W]
Servo amplifier
Regenerative resistor
Normal Cooling
Resultant
resistance
[
Ω
]
Number of
resistors
MR-J4-11KA(-RJ) GRZG400-0.8
Ω
500 800 3.2
4
MR-J4-15KA(-RJ) GRZG400-0.6
Ω
3
MR-J4-22KA(-RJ) GRZG400-0.5
Ω
850 1300
2.5
5
MR-J4-11KA4(-RJ) GRZG400-2.5
Ω
500 800
10
4
MR-J4-15KA4(-RJ)
MR-J4-22KA4(-RJ)
GRZG400-2
Ω
850 1300 10
5
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......