11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 40
(4) Mounting hole machining dimensions
When the power regeneration converter is installed to an enclosed type cabinet, mount the heat
generating area of the converter outside the box to provide heat generation measures. At this time, the
mounting hole having the following dimensions is machined in the box.
[Unit: mm]
Power regeneration
converter
a b D AA
BA
FR-RC-15K 260
412
10
200
432
FR-RC-30K 330
562
10
270
582
FR-RC-55K 470
642
12
410
670
FR-RC-H15K
FR-RC-H30K
330 562 10 270
582
FR-RC-H55K 470
642
12
410
670
(AA)
(BA)
b
a
D hole)
(2-
(Mounting hole)