11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 44
(3) Connection diagram
POINT
In this configuration, only the STO function is supported. The forced stop
deceleration function is not available.
(a) 200 V class
RES
RA1
EM1
SON
DOCOM
ALM
DICOM
RA3
EM1
SON
RA3
RA2
MC
MCCB
R/L11
S/L21
T/L31
S2/L22
R2/L12
T2/L32
FR-CVL
MC
RA2 EM1
RESET
MC
SK
R2/L1
S2/L2
N/L-
P24
SD
RDYB
RDYA
RSO
SE
SD
P/L+
T2/L3
R/L11
S/L21
T/MC1
RES
L11
L21
P4
N-
U
V
W
U
V
W
CN2
FR-CV
B
C
A
RA1
RA1
(Note 2)
3-phase
200 V AC to
230 V AC
OFF
ON
(Note 1)
(Note 1)
Servo motor
Servo amplifier
(Note 5)
(Note 7)
24 V DC (Note 8)
(Note 1)
24 V DC (Note 8)
(Note 2)
(Note 4)
(Note 1, 6)
24 V DC (Note 8)
(Note 3)
Note 1. Configure a sequence that will shut off main circuit power at the follow cases.
FR-CV or servo amplifier alarm occurs.
EM1 (forced stop 1) turns off.
2. For the servo amplifier, configure a sequence that will switch the servo-on after the FR-CV is ready.
3. For the FR-CV, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input. Configure a
sequence that will make the servo inoperative when the RSO signal is on.
4. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm occurs in
the FR-CV.
5. When using FR-CV, always disconnect wiring between P3 and P4 terminals.
6. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
7. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
8. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......