11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 49
Power regeneration
common converter
FR-CV-H_
Item
22K 30K 37K 55K
Total of connectable servo amplifier
capacities
[kW]
11 15 185
27.5
Maximum servo amplifier capacity
[kW]
11
15
15
22
Total of connectable servo
motor rated currents
[A]
43 57 71 110
Short-time rating
Total capacity of applicable servo motors, 300% torque, 60 s
(Note 1)
Output
Regenerative
braking torque
Continuous rating
100% torque
Rated input AC voltage/frequency
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
Permissible AC voltage fluctuation
3-phase 323 V AC to 528 V AC, 50 Hz/60 Hz
Permissible frequency fluctuation
±5%
Power supply
Power supply capacity (Note 2) [kVA]
41
52
66
100
IP rating (JEM 1030), cooling method
Open type (IP00), forced cooling
Ambient temperature
-10 °C to 50 °C (non-freezing)
Ambient humidity
90 %RH or less (non-condensing)
Environment
Ambience
Indoors (no direct sunlight), free from corrosive gas,
flammable gas, oil mist, dust, and dirt
Altitude, vibration resistance
1000 m or less above sea level, 5.9 m/s
2
Molded-case circuit breaker or earth-
leakage current breaker
50AF
50A
60AF
60A
100AF
75A
100AF
100A
Magnetic
contactor
S-N25 S-N35 S-N50 S-N65
Note 1. This is the time when the protective function of the FR-CV-(H) is activated. The protective function of
the servo amplifier is activated in the time indicated in section 10.1.
2. The specified value is the power supply capacity of FR-CV-(H). The total power supply capacities of
the connected servo amplifiers are actually required.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......