12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 20
(2) Transmission error
(a) [AL. E5 ABS time-out warning]
In the ABS transfer mode, the servo amplifier processes time-out below, and displays [AL. E5] when
a time-out error occurs.
[AL. E5 ABS time-out warning] is cleared when ABSM changes from off to on.
1) ABS request off-time time-out check (applied to 32-bit absolute position data in 2-bit units
checksum)
If the ABS request signal is not turned on by the programmable controller within 5 s after ABST is
turned on, this is regarded as a transmission error and [AL. E5 ABS time-out warning] is output.
OFF
ON
OFF
ON
OFF
ON
5 s
ABSM
ABSR
ABST
[AL. E5]
Signal is not turned ON
No
Yes
2) ABS request on-time time-out check (applied to 32-bit absolute position data in 2-bit units
checksum)
If the ABSR is not turned off by the programmable controller within 5 s after ABST is turned off,
this is regarded as the transmission error and [AL. E5 ABS time-out warning] is output.
OFF
ON
OFF
ON
OFF
ON
5 s
ABSM
ABSR
ABST
[AL. E5]
Signal is not turned OFF
No
Yes
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......