17. FULLY CLOSED LOOP SYSTEM
17 - 19
17.3.3 Fully closed loop control error detection functions
If fully closed loop control becomes unstable for some reason, the speed at servo motor side may increase
abnormally. The fully closed loop control error detection function is a protective function designed to pre-
detect it and stop operation.
The fully closed loop control error detection function has two different detection methods, speed deviation
and position deviation, and errors are detected only when the corresponding functions are enabled by setting
[Pr. PE03 Fully closed loop function selection 2].
The detection level setting can be changed using [Pr. PE06] and [Pr. PE07].
(1) Parameter
The fully closed loop control error detection function is selected.
Fully closed loop control error detection function
0: Disabled
1: Speed deviation error detection
2: Position deviation error detection
3: Speed deviation error, position deviation error detection
(Initial value)
0
0
0
[Pr. PE03]
(2) Fully closed loop control error detection functions
Servo motor
Linear encoder
1) Servo motor-side feedback speed [r/min]
2) Servo motor-side feedback position [pulse]
(load side equivalent value)
3) Load-side feedback speed [r/min]
4) Load-side feedback position [pulse]
(a) Speed deviation error detection
Set [Pr. PE03] to "_ _ _ 1" to enable the speed deviation error detection.
Speed deviation error detection
1
[Pr. PE03]
The function compares the servo motor-side feedback speed (1)) and load-side feedback speed (3)).
If the deviation is not less than the set value (1 r/min to the permissible speed) of [Pr. PE06 Fully
closed loop control speed deviation error detection level], the function generates [AL. 42.2 Servo
control error by speed deviation] and stops the motor. The initial value of [Pr. PE06] is 400 r/min.
Change the set value as necessary.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......