APPENDIX
App. - 11
(2) 1-phase input for MR-J4 1-axis servo amplifier
MCCB
or fuse
Controller
STO
Encoder cable
(1-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
(Note)
MCCB
or fuse
PE
L11
L21
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
C
P+
D
N-
U/V/W/PE
CN2
CN1
CN8
L2L3
Note. When the wire sizes of L1 and L11 are the same, MCCB or fuse is not required.
(3) 3-phase input for MR-J4 multi-axis servo amplifier
MCCB
or fuse
Controller
STO
Encoder cable
(3-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
(Note)
MCCB
or fuse
PE
L11
L21
MC
Servo
amplifier
Cabinet side
Machine side
CN1
CN8
Servo motor
Servo motor
Servo
motor
CNP1
(L1 L2 L3)
CNP3C
CN2A
CNP3B
CN2B
CN2C
CNP2
CNP3A
Note. When the wire sizes of L1 and L11 are the same, MCCB or fuse is not required.
(4) 1-phase input for MR-J4 multi-axis servo amplifier
MCCB
or fuse
Controller
STO
Encoder cable
(1-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
(Note)
MCCB
or fuse
PE
L11
L21
MC
Servo
amplifier
Cabinet side
Machine side
CN1
CN8
Servo motor
Servo motor
Servo
motor
CNP1
(L1 L2 L3)
CNP3C
CN2A
CNP3B
CN2B
CN2C
CNP2
CNP3A
Note. When the wire sizes of L1 and L11 are the same, MCCB or fuse is not required.
The control circuit connectors described by rectangles are safely separated from the main circuits described
by circles.
The connected motors will be limited as follows.
Summary of Contents for MR-J4-100A
Page 9: ...A 8 MEMO ...
Page 61: ...1 FUNCTIONS AND CONFIGURATION 1 44 MEMO ...
Page 67: ...2 INSTALLATION 2 6 MEMO ...
Page 137: ...3 SIGNALS AND WIRING 3 70 MEMO ...
Page 261: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 291: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO ...
Page 299: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 319: ...9 OUTLINE DRAWINGS 9 20 MEMO ...
Page 461: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 36 MEMO ...
Page 511: ...14 COMMUNICATION FUNCTION 14 38 MEMO ...
Page 559: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 583: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 621: ...APPENDIX App 38 ...
Page 639: ......