background image

 

 

 

 

 

 

POUR L’INSTALLATEUR

FÜR INSTALLATEURE

FOR INSTALLER

Air to Water Heat Pump

PUHZ-W

 • 

HA series

PUHZ-HW

 • 

HA series

PER L’INSTALLATORE

PARA EL INSTALADOR

VOOR DE INSTALLATEUR

INSTALLATIEHANDLEIDING

Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het 
installeren van de airconditioner begint.

MANUAL DE INSTALACIÓN

Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad inte-
rior antes de instalar la unidad de aire acondicionado.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d’installazione dell’unità 
interna prima di installare il condizionatore d’aria.

Nederlands

Español

Italiano

Dansk

Svenska

INSTALLATION MANUAL

For safe and correct use, read this manual as well as the indoor unit installation manual thoroughly before in-
stalling the unit.

INSTALLATIONSHANDBUCH

Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanlei-
tung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.

MANUEL D’INSTALLATION

Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil 
intérieur pour une utilisation sûre et correcte.

English

Deutsch

Français

01̲ BH79D067L02̲EN.indd   1

01̲ BH79D067L02̲EN.indd   1

2009/06/03   9:50:13

2009/06/03   9:50:13

Summary of Contents for PUHZ-HW*HA series

Page 1: ...curo e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unit interna prima di installare il condizionatore d aria Nederlands Espa ol Italiano Dansk Svenska INSTALLA...

Page 2: ...ation has been completed make sure that refrigerant does not leak If refrigerant leaks into the room and comes into contact with the flame of a heater or portable cooking range poisonous gases will be...

Page 3: ...ods or telephone grounding lines If the unit is not properly grounded there may be a risk to get an electric shock Make sure to use circuit breakers ground fault interrupter isolating switch B fuse an...

Page 4: ...ion the unit so that the outlet air can blow at right angle to the seasonal wind direction if possible Fig 2 4 B Wind direction A M10 3 8 bolt B Base C As long as possible D Vent E Set deep in the gro...

Page 5: ...hin the allowable range specified in our technical data etc If the unit is used out of the allowable range the parts of unit might be damaged 5 2 Water quality condition The water in a system should b...

Page 6: ...terminal However between S3 and S1 these terminals are NOT electrically insulated by the transformer or other device Notes 1 Wiring size must comply with the applicable local and national codes 2 Powe...

Page 7: ...er ant within the compressor This is not a malfunction Perform the following proce dures 1 Remove the wires from the compressor and measure the insulation resistance of the compressor 2 If the insulat...

Page 8: ......

Page 9: ...0 500 1000 400 600 1000 2000 300 1000 1500 500 800 150 1000 1500 400 600 2000 3000 300 500 Fig 2 5 Fig 2 6 Fig 2 7 Fig 2 8 Fig 2 9 Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 13 Fig 2 14 Fig 2 15 Fig 2 16 Fig 2...

Page 10: ...K BH79D067L02 Printed in Japan Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the resident...