194
<4> Movement setting : The condition and the signal output operation when the button ON can be set.
The condition can be selected as follows. Please set the signal number etc. when
you make the signal state the condition. When the button is ON or OFF, the
condition is judged.
- Unconditionally
-
State of the specified Input signal
-
State of the specified output signal
The signal output operation can be selected as follows. Please set the signal
number etc. when you output the signal.
- Done
nothing
-
Output the specified output signal
Operation setting can be set up to two.
Two operation settings operate individually by using each condition.
Moreover, when High and Low are set to output to the same signal, and both
conditions become true, the Condition2 is given priority.
If the operation is set signal output, when the button is OFF, the signal is output in
the state opposite High/Low state at the time of ON.
Example of setting the movement of button
For example:
The button that output signal number 20 to High when input signal number 20 is High.
(1) A default value of “Button operating
condition” window is shown in a right
picture.
(2) Set the condition of operation.
Tap <d>, and select the signal type.
When things except "Unconditionally" are
selected, the input area of signal number
and the combo box to select the state are
displayed.
Now, select "input signal".
<d>
Summary of Contents for R56TB
Page 1: ...Mitsubishi Industrial Robot CR750 CRn 700 Series R56TB R57TB Instruction Manual BFP A8684 F...
Page 4: ...8 CAUTION CAUTION WARNING...
Page 6: ......
Page 12: ......
Page 126: ...114 Current2 a...
Page 173: ...161 17 4 9 5 Hand 17 4 9 6 Warm up...
Page 174: ...162 17 4 9 7 Start each slot 17 4 9 8 Stop each slot...
Page 175: ...163 17 4 9 9 Servo ON OFF each robot 17 4 9 10 Machine lock each robot...
Page 179: ...167...