3Installing the option devices
Installation the pneumatic hand set
(
4A-HP02/HP02E
)
3-35
3.2 Installation the pneumatic hand set
(
4A-HP02/HP02E
)
shows the construction of the pneumatic hand set and the installation procedure and
shows
the configuration equipment which correspond with the
.
Fig.3-3
:
Pneumatic hand set installation procedures
Table 3-3
:
Configuration for the pneumatic hand set
Number
Part name
Model
Quantity
Description
<
1
>
Pneumatic hand
1
E-HP0
1
/
1
E-HP0
1
E
1
Hand input cable with pneumatic coupling
<2>
Pneumatic hand interface
2A-RZ365/375
1
Interface board (Install on the controller)
<3>
Solenoid valve set
1
E-VD0
1
/
1
E-VD0
1
E
1
Comes with two M3x25 socket head bolts
<4>
Hand curl tube
(2 tubes per set)
1
E-ST0402C
1
<5>
Socket head bolts
M5x
1
6
4
<6>
Socket head bolts
M3x
1
2
4
<7>
Adapter
BU
1
44D697H0
1
1
This item is needed for installing <
1
> above.
View from A
A
<1> Pneamatic hand
<6> M3×12(4)
<5> M5×16(4)
<7> Hand adapter
<4> Hand curl tube
Hand check cable
Mechanical interface
φ5 hole
Foream
CON1H
Coupling "2"
Coupling "1"
<7> <5>
<1> <6>
<3>
Adapter
Pneumatic hand
(Hand check cable)
Attaches to pneumatic hand
Hand curl tube
<4>
Solenoid valve set