10-36
Chapter 10 COOLING SYSTEM
2.12 Water pump for Air cooler Cooling - Assemble
Water pump for Air cooler Cooling - Assemble
Apply sealant (ThreeBond 1102) to
outer peripheral surface of unit seal.
Application of grease
Fill with 31 grams grease.
Replace
22.5 ± 2.25 N·m
{2.29 ± 0.23 kgf·m}
[16.6 ± 1.66 lbf·ft]
Application of sealant
(ThreeBond 1102)
Application of Loctite
Make it flush
0.5 to 1.1 mm
[0.020 to 0.043 in.]