13-4
Chapter 13 ADJUSTMENT AND OPERATION
1.4.2 Fuel Filter (Standard Spec) - Bleed Air
(1)
Loosen the air vent plug of fuel filter by approx 1.5
turns.
(2)
Feed fuel by moving the priming pump up and down.
(3)
When fuel flowing from vent holes no longer contains
air bubbles, tighten the air vent plugs to the specified
torque.
Fuel Filter (Standard Spec) - Bleed Air
1.4.3 Air Filter (Change Over Spec) - Bleed Air
(1)
Switch the filter to bleed air, and loosen the air vent
plug of fuel filter by approx 1.5 turns.
(2)
Feed fuel by moving the priming pump up and down.
(3)
When fuel flowing from vent holes no longer contains
air bubbles, tighten the air vent plugs to the specified
torque.
(4)
Turn the changeover cock to the position during opera-
tion.
Air Filter (Chnge Over Spec) - Bleed Air
1.4.4 Fuel Injection Pump - Bleed Air
(1)
Loosen the air vent plugs of fuel injection pump by
approx 1.5 turns.
(2)
Feed fuel by moving the priming pump up and down.
(3)
When fuel flowing from vent holes no longer contains
air bubbles, tighten a air vent plug leaving one plug un-
tightened. Lock the priming pump by turning the cap
clockwise while pushing it down. Then tighten the last
air vent plug.
Note:(a) To check the function of check valve, tighten the all
air vent plugs, then lock the priming pump cap.The
priming pump cap resists the push-in, but the check
valve opening pressure is stabilized and the valve
function is verified with this procedure.
(b) Thoroughly wipe off fuel spilled out of air vent
plug.
Fuel Injection Pump - Bleed Air
If the air vent plugs, threads of bracket or sealing
washers are damaged, replace them with new ones.
Air vent plug
8 to 10 N·m
{0.8 to 1.0 kgf·m}
[5.9 to 7.4 lbf·ft]
Priming pump
cap
If the air vent plugs, threads of bracket or sealing
washers are damaged, replace them with new ones.
Right side
filter
Left side
filter
Air vent plug
Position during
operation
A: Air vent location of left side filter
B: Air vent location of right side filter
Pin
Pin
Changeover cock
Changeover cock
A
B
9 ±1 N·m {0.9 ± 0.1 kgf·m}
[ 6.6 ± 0.7 lbf·ft]
Priming pump
cap
Air vent plug
6 ± 1 N·m
{0.6 ± 0.1 kgf·m}
[4.4 ± 0.7 lbf·ft]
Summary of Contents for S12A2
Page 1: ...SERVICE MANUAL September 2010 Pub No 99269 20170 199269 20170 ...
Page 2: ......
Page 16: ......
Page 20: ......
Page 42: ......
Page 44: ......
Page 68: ......
Page 69: ...3 1 Chapter 3 SERVICE TOOLS 1 Special Tools 3 3 ...
Page 70: ......
Page 78: ......
Page 82: ......
Page 136: ......
Page 174: ......
Page 218: ......
Page 220: ......
Page 242: ......
Page 244: ......
Page 294: ......
Page 310: ......
Page 320: ......
Page 322: ......
Page 334: ......
Page 354: ......