20
10-4. TROUBLE CRITERION OF MAIN PARTS
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA
Part name
Check method and criterion
Figure
Defrost thermistor (RT61)
Fin temperature
thermistor (RT64)
Ambient temperature
thermistor (RT65)
Outdoor heat exchanger
temperature thermistor
(RT68)
Measure the resistance with a tester.
Refer to “Inverter P.C. board” in "10-6. TEST POINT DIAGRAM AND
VOLTAGE”, for the chart of thermistor.
Discharge temperature
thermistor (RT62)
Measure the resistance with a tester. Before measurement, hold the
thermistor with your hands to warm it up.
Refer to “Inverter P.C. board” in "10-6. TEST POINT DIAGRAM AND
VOLTAGE”, for the chart of thermistor.
Compressor
Measure the resistance between terminals with a tester.
(Temperature: 14 to 104°F (-10 to 40°C))
Normal (Ω)
KA09
KA12
KA15/18
U-V
U-W
V-W
1.36 to 1.93 1.52 to 2.17 0.78 to 1.11
Outdoor fan motor
Measure the resistance between lead wires with a tester.
(Temperature: 14 to 104°F (-10 to 40°C))
Color of lead wire
Normal (Ω)
KA09/12/15
KA18
RED – BLK
BLK – WHT
WHT – RED
28 to 40
11 to 16
R. V. coil (21S4)
Measure the resistance with a tester.
(Temperature: 14 to 104°F (-10 to 40°C))
Normal (kΩ)
0.97 to 1.38
Expansion valve coil
(LEV)
Measure the resistance with a tester.
(Temperature: 14 to 104°F (-10 to 40°C))
Color of lead wire
Normal (Ω)
WHT – RED
37 to 54
RED – ORN
YLW – BRN
BRN – BLU
W
U
V
WHT
RED BLK
WHT
RED BLK
LEV
WHT
RED
ORN
Y
LW
BRN
BLU
OCH467C
Summary of Contents for SUZ-KA09NA