![background image](http://html1.mh-extra.com/html/mitsubishi/vs-sh10u/vs-sh10u_setup-and-installation-manual_1809617051.webp)
VS-SH10U Set-up and Installation Manual
51
5.6.10. e (Error Detection)
Function: To get error states. If error is detected, system automatically starts shutdown process
and becomes stand-by mode. Detected error status is obtained in stand-by mode.
Detected errors are cleared on next start-up. If any errors are detected again, system
replies the error information. If not, it replies “no error.”
Format:
ID
e
Response:
ID
e
info
Last detected error information
0
Fan stop
1
Lamp changer mechanical failure or no workable lamp
2
DMD control circuit failure
3
DMD control circuit failure
4
Lamp changer control circuit failure
5
Internal SRAM failure
6
(not defined)
7
Power failure
info
n
No error
5.6.11. ISA
(Lamp-A Status)
Function: To get lamp-A status.
Format:
ID
ISA
Response:
ID
ISA
status
Lamp-A status
0
New
1
Used
status
2
Junk
5.6.12. ISB
(Lamp-B Status)
Function: To get lamp-B status.
Format:
ID
ISB
Response:
ID
ISB
status
Lamp-B status
0
New
1
Used
status
2
Junk
Summary of Contents for VS-SH10U
Page 1: ...DLPTM Projector VS SH10U Set up and Installation Manual August 30 2002...
Page 8: ...First edition 8 1 2 Outline drawings 1 2 1 Circuit Box unit mm...
Page 9: ...VS SH10U Set up and Installation Manual 9 1 2 2 Optical Unit unit mm...
Page 56: ...First edition 56 6 2 6 axis adjuster Model Screw holes VS SH10U c e h j...