5.6.13. ST1
(Status Information)
Function: To get projector status information.
Format:
ID
ST1
Response:
ID
ST1
info
Indicate status with HEX2 bytes ASCII code corresponding to 8 bits
info
00 – ff
The functions of each bit are as follows.
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
r
r
r
p-seq
mt
change
light
signal
signal
0: input signal on
1: input signal off
* It is uncertain value, if p-seq bit is 1.
light
0: lamp turning off
1: lamp turning on
* It is uncertain value, if p-seq bit is 1.
change
0: lamp exchanging prenotice off
1: lamp exchanging prenotice on
mt
0: maintenance request off
1: maintenance request on
The detailed maintenance request can be obtained by MT
command.
STR2 command execution sets “0”.
p-seq
0: sig, light information is available
1: sig, light information is invalid. (It sometimes occurs on
start-up process.)
r
: reserved
5.6.14. ST2
(Lamp Timer Value)
Function: To get lamp timer value.
Format:
ID
ST2
Response:
ID
ST2
time
Indicate lamp timer value with HEX6 bytes ASCII code.
time
000000 – ffffff
Lamp timer value
Example:
If lamp timer value is 961 hours,
ID ST2 0003c1 ¥r
(“¥r” stands for a CR code (0Dh))
Summary of Contents for VS-SH10U
Page 1: ...DLPTM Projector VS SH10U Set up and Installation Manual August 30 2002...
Page 8: ...First edition 8 1 2 Outline drawings 1 2 1 Circuit Box unit mm...
Page 9: ...VS SH10U Set up and Installation Manual 9 1 2 2 Optical Unit unit mm...
Page 56: ...First edition 56 6 2 6 axis adjuster Model Screw holes VS SH10U c e h j...