![background image](http://html1.mh-extra.com/html/mitsubishi/vs-sh10u/vs-sh10u_setup-and-installation-manual_1809617054.webp)
First edition
54
5.6.18. MT
(Maintenance request information)
Function: To indicate error information of luminance sensor and lamp exchanging, result of lamp
exchanging execution and set timer value.
Format:
ID
MT
Response:
ID
MT
info
:
time
Indicate error information and lamp exchanging execution result.
info
0000 –
ffff
Indicate status with 4 bytes ASCII code corresponding to 16 bits.
bit15 bit14 bit13 bit12 bit11 bit10
bit9
bit8
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
mtf
mte
mtd
mtc
mtb
mta
mt9
mt8
mt7
mt6
mt5
mt4
mt3
mt2
mt1
mt0
mt0: error in lamp eject
mt1: error in lamp insert
mt2: reserved
mt3: reserved
mt4: sensor failure
mt5: reserved
mt6: reserved
mt7: reserved
mt8: reserved
mt9: reserved
mta: not execute lamp initial position setting
mtb: not execute manual lamp exchanging
mtc: not execute brown-out lamp exchanging
mtd: not execute burn-out lamp exchanging
mte: execute brown-out lamp exchanging
mtf: execute burn-out lamp exchanging
Set timer value
time
000000 –
ffffff
Indicate set timer value with 6 bytes ASCII code.
Example:
If detected status is 0000001100010000 and set timer value is 961 hours,
ID MT 0310:0003c1 ¥r
(“¥r” stands for a CR code (0Dh))
Response to MT command just after STR2 command issuing
ID MT 0000:000000 ¥r
(“¥r” stands for a CR code (0Dh))
Summary of Contents for VS-SH10U
Page 1: ...DLPTM Projector VS SH10U Set up and Installation Manual August 30 2002...
Page 8: ...First edition 8 1 2 Outline drawings 1 2 1 Circuit Box unit mm...
Page 9: ...VS SH10U Set up and Installation Manual 9 1 2 2 Optical Unit unit mm...
Page 56: ...First edition 56 6 2 6 axis adjuster Model Screw holes VS SH10U c e h j...