MFP250 / 400 / 800
Sequence
76609594EN-MFP-NH-V2.0.docx 33/40
5.2
Data output format RS232
String
Description
Number of digits
Prg
Program number
3
Space
1
AX
Axis 1 or 2
2
Space
1
s1Fs_um
Distance to part after search intensity force
[µm]
7
Space
1
s1Fw_um
Distance to part after welding force [µm]
7
Space
1
s3P1_um
Displacement pulse 1 [µm]
7
Space
1
s2P1_um
Current switch-off threshold pulse 1[µm]
7
Space
1
s3P2_um
Displacement pulse 2 [µm]
7
Space
1
s2P2_um
Current switch-off threshold pulse 2 [µm]
7
Space
1
FwP1_N
Welding force pulse 1 [N]
7
Space
1
FwP2_N
Welding force pulse 2 [N]
7
Space
1
E+
Out of limit Max. (MNC)
1 = asterisk (*)
Space
1
E-
Out of limit Min. (MNC)
1 = asterisk (*)