CHAPTER 6: PROCESS DEFINITIONS AND WELD FUNCTIONS
MODEL 250DP DUAL PULSE
RESISTANCE WELDING POWER SUPPLY
6-2
990-280
(c) Run State showing Weld 1 Energy Level.
(d) Run State with the Weld Sentry Air
Head using Rollspot Weld Function.
Installed and Sentry Status Displayed
STANDBY State
The 250DP is waiting for a mandatory event to occur such as:
x
The force firing switch in an air head to close, or
x
The schedule number information to be placed on the terminals of the CONTROL SIGNALS
connector, or
x
Waiting to be reset to another schedule after a stop command in a chained schedule.
PROGRAM State
In this state, the 250DP will allow you to change and save (write to permanent memory) any weld
schedule. Press [PROG] to enter the PROGRAM state, which is signified by the legend
ű
( PROGRAM
ű
( in the lower right-hand corner of the screen. In those units which include the
Weld Sentry option, the PROGRAM state also allows you to change the measurement unit, the limits
related to the Weld Sentry program, and the other parameters associated with the Weld Sentry.