CHAPTER 6: PROCESS DEFINITIONS AND WELD FUNCTIONS
MODEL 250DP DUAL PULSE
RESISTANCE WELDING POWER SUPPLY
6-6
990-280
x
When the 250DP is initiated, or
x
After Pulse 1, or
x
After Pulse 2, or
x
During the cool or off periods, or
x
When the 250DP is in the RUN state waiting for the welding sequence to start.
The status of each relay, shown on Lines 6 and 7, is set in the PROGRAM state and is confirmed, in real
time, in the RUN state.
Repeat Function
This function provides an automatic repeat of the weld sequence for simple automated air actuated
applications. It is ideal for volume production which requires a single schedule.
NOTE:
Repeat can only be used with an air actuated weld head.
You should specify the off time so that it is sufficient to allow the weld head to open the electrodes, and
to allow you to reposition the work piece before the entire welding sequence repeats. Footswitch Weld
Abort OFF is not permitted with the repeat function.
The PROGRAM State Screen for the Repeat Function.
NOTE: The OFF Period is only used with this function.