APPENDIX A: TECHNICAL SPECIFICATIONS
MODEL 250DP DUAL PULSE
RESISTANCE WELDING POWER SUPPLY
A-4
990-280
Table A-2. Welding Speed
1500 μF Capacitor
3000 μF Capacitor BANK
Percent Full Energy
Rep Rate
(welds/min)
Hit Rate
(welds/min)
Rep Rate
(welds/min)
Hit Rate
(welds/min)
2%
300 300 300
300
10%
290 290 250
280
25%
260 260 175
180
50%
210 240 120
124
75%
160
160
95
99
100%
125
125
65
70
Conditions: 25
q
C Ambient, Nominal Line Voltage, 60 Hz.
In dual pulse operation, the repetition rate or hit rate for each individual pulse may be calculated as follows:
RR
1
= First Pulse Rep Rate (Hit Rate)
RR
2
= Second Pulse Rep Rate (Hit Rate)
Calculate RR
(1+2),
Rep Rate (Hit Rate) for dual pulse operation.
(RR
1
) (RR
2
)
RR
(1+2)
=
RR
1
+ RR
2
For example, if the energy level of Pulse 1 is 25% and Pulse 2 is 75%, the repetition rate for the dual pulse
weld would be:
(175) (95)
RR
(1+2)
= = 61.57 welds/min.