APPENDIX A: TECHNICAL SPECIFICATIONS
MODEL 250DP DUAL PULSE
RESISTANCE WELDING POWER SUPPLY
A-10
990-280
Footswitch Weld Abort Feature
The footswitch weld abort feature is controlled from the options menu.
Footswitch Weld Abort On
With FOOTSWITCH WELD ABORT ON selected, the welding sequence is initiated by the closure of
the initiation switch, and continues to its conclusion as long as the initiation switch remains closed. If
the initiation switch or the force firing switch open during the welding sequence, the sequence will
terminate. FOOTSWITCH WELD ABORT ON is preferred since it allows the operator to abort the
welding sequence by releasing the footswitch, or footpedal in the case of a manual head.
Footswitch Weld Abort Off
With FOOTSWITCH WELD ABORT OFF selected, the welding sequence is initiated by a single,
momentary, closure of the initiation switch. Opening the initiation switch during the welding sequence
will
not
terminate the welding sequence.
The initiation switch must open and re-close in order to start the next sequence. FOOTSWITCH WELD
ABORT OFF is used in automated process control systems where operator intervention is not an issue.
Firing Switch Type
The 250DP can use as an input signal either a:
x
Single pole, single throw switch
x
Double pole, double throw (3-wire) switch, or an
x
Optical switch.
The input signal will indicate when the weld head has applied the proper force to the workpiece. Weld
heads with single pole firing switches should be connected to the MECHANICAL FIRING SWITCH
connector. A 3-wire switch or optical firing switch, either of which should be connected to the OPTICAL
FIRING SWITCH connector, eliminates switch bounce (which causes false triggering), and should be used
when the welding speed exceeds 1.5 welds per second.
Firing Circuit
The firing circuit requires external contact closure or low logic level for firing. Internal filtering
prevents premature firing due to radio frequency interference. The 250DP will automatically detect that
the system is using a 3-wire switch whenever it enters the RUN state if Pin 1 is shorted to Pin 2.