IPB-5000A
6. Discription of Display Screens
6-13
(8) STATUS Screen
Change the initial setting of
IPB-5000A
here in this screen.
According to customer’s preference, precise setting can be obtained.
①
STATUS (1/2) Screen
(
a
)
WELD TRANS
Set a transformer.
Select it among
ITE-142A6
,
ITD-360A6
and
ITB-780A6
.
(
b
)
CONTROL
Set a weld control method.
CURR :
Constant Current Control
VOLT :
Constant Voltage Control
COMB :
Constant Current/Constant Voltage Combination Control
POWER :
Constant Power Control
(
c
)
START SIG. TIME
Set a delay time defined as the time period which elapses from an input of
Start Signal to a beginning of weld sequence.
The setting can eliminate the chattering movement of a start switch.
Select the set value among 20ms, 10ms, 5ms and 1ms.
If a chattering-proof switch can be used, shortest Delay Time can be
obtained.
(
d
)
START SIG. HOLD
A self-sustaining timing at starting can be selected.
SQ HOLD:
Self-sustaining action works from the starting of squeeze
sequence
WE HOLD:
Self-sustaining action works from the starting of weld
sequence
NO HOLD:
NO self-sustaining action works. Input a start signal until
the end of sequence.
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)