IPB-5000A
6. Discription of Display Screens
6-17
(
c
)
COUNTER
Set the mode of Counter.
TOTAL
Count-up (increment of +1) is done despite the result of the
judgment in monitoring when the current is supplied.
Judgment in Monitor
Counting Manner
GOOD
Count-up
CAUTION
Count-up
NG
Count-up
GOOD
Count-up is done if the judgment is
GOOD
in current-supplied
monitoring.
Judgment in Monitor
Counting Manner
GOOD
Count-up
CAUTION
No Count-up
NG
No Count-up
WORK
Count-up is not done if the judgment is
NG
in current-supplied
monitoring.
Judgment in Monitor
Counting Manner
GOOD
WELD
Counter counts-up.
WORK
Counter counts-up (increment
of +1) when
WELD
Counter reached
the set value.
CAUTION
WELD
Counter counts-up.
WORK
Counter counts-up (increment
of +1) when
WELD
Counter reached
the set value.
NG
WELD
Counter does not count-up.
WELD
Counter is reset to 0 (zero)
when NG is reset.
WORK
Counter does not count-up.
Note: The period for retaining the memory of counted numbers is
approximately 10 days since the day when a power supply is turned
off at latest.
(
d
)
PRESET (TOTAL/GOOD)
Input the preset value of
TOTAL/GOOD
Counter.
(
e
)
PRESET (WORK)
Input the preset value of
WORK
Counter.
(
f
)
PRESET (WELD)
Input the preset value of
WELD
Counter.
(
g
)
BACK
Displays
②
STATUS (2/2)
Screen of the previous page.