IPB-5000A
7. Basic Operation
7-2
Item
Value Item Value
SCHEDULE#
15
UP SLOPE
at
WE1
2ms
SQZ
400ms
UP SLOPE
at
WE2
2ms
WE1
20ms
DOWN SLOPE
at
WE1
5ms
COOL
2ms
DOWN SLOPE
at
WE2
5ms
WE2
20ms
CURR
at
WE1
1kA
HOLD
10ms
CURR
at
WE2
2kA
(6) For the test of welding, press
MENU
Key
on Front Panel, select
MONITOR
and press
ENTER Key
.
MONITOR
Screen
is displayed.
(7) Press
WELD Key
on Front Panel to
light up
WELD Lamp
(LED).
(8) Set ON (Closed circuit) to
WELD
ON/OFF
on
Connecting Terminal
Strip for External Input/Output
Signal
at Rear Panel.
Make sure that the letter of
READY
on the upper right of Screen is
green-lighted.
(9) Set ON (Closed circuit) to
SCH1, SCH2, SCH4
and
SCH8
on
Connecting Terminal
Strip for External Input/Output Signal
at Rear Panel for setting
SCHEDULE#15
.
P OW ER
START
I P B - 5 0 0 0 A
CURSOR
WELD
MENU
RESET
ENTER
+
-
WELDING POWER SUPPLY