IS-120B
9. Maintenance
9-1
9. Maintenance
(1) Replacement of Battery
The life expectancy of the lithium battery installed to this equipment is five years.
Following the procedures below, replace the battery before it runs out.
When replacing the lithium battery, be sure to turn off the main power
and wait for at least 5 minutes, then replace the battery so as not to get
an electric shock.
ATTENTION
・
The stored data may be lost when the battery is replaced. Before replacing the
battery, take the record of the data in
10. (5)Schedule data Table
.
・
When replacing the battery, work carefully to prevent damage to the
printed circuit board and parts mounted on it.
①
After checking the battery is dead, remove the outer cover. The PC board, on
which the battery is mounted, is located rear left of the power supply.
②
Insert your forefinger between the battery holder and the lithium button battery.
Pinch the battery with your thumb and forefinger and pull it out.
③
Push in a new battery firmly with battery positive sign (+) coming to holder
positive sign (+).
④
Check that the battery is correctly set in the battery holder. Re-place the cover
and secure it with screws.
IS-120B
Rear
①
②
①
Button-type lithium
battery
JIS CR2450 3V
②
Battery holder
[Printed circuit board]
DANGER
!