IS-120B
10. Specifications
10-1
10. Specifications
(1) Controller Specifications
Model name
IS-120B
Overvoltage category
Category
III
Incoming power supply
Three-phase
480 VAC/440 VAC/400 VAC/380 VAC/240 VAC/220 VAC
(
Voltage fixed to a customer-specified one when shipped.
)
+10%/-15%, 50 Hz / 60 Hz
Control power supply
Stepped down from incoming power supply
Input power supply
for valve
100 VAC or 24 VDC
(
Maximum output current: 0.5 A
)
Output voltage
(Single-phase)
648V (Peak value at input voltage of 480 VAC)
600V (Peak value at input voltage of 440 VAC)
540V (Peak value at input voltage of 400 VAC)
510V (Peak value at input voltage of 380 VAC)
325V (Peak value at input voltage of 240 VAC)
300V (Peak value at input voltage of 220 VAC)
Max. output current
200A (Peak value) (Duty cycle: 8%)
Output frequency
1 kHz (800 Hz and 600 Hz selectable)
Max. capacity
130 kVA (At input voltage of 480 VAC)
120 kVA (At input voltage of 440 VAC)
108 kVA (At input voltage of 400 VAC)
102 kVA (At input voltage of 380 VAC)
65 kVA (At input voltage of 240 VAC)
60 kVA (At input voltage of 220 VAC)
Rated capacity
52 kVA (At input voltage of 480 VAC)
48 kVA (At input voltage of 440 VAC)
43 kVA (At input voltage of 400 VAC)
41 kVA (At input voltage of 380 VAC)
26 kVA (At input voltage of 240 VAC)
24 kVA (At input voltage of 220 VAC)
Average max. duty
cycle
(
See
10.(4)Duty Cycle
)
At output current 200A (Duty cycle: 8%)
At output current 150A (Duty cycle: 12.5%)
At output current 100A (Duty cycle: 23%)
At output current 38A (Duty cycle: 100%)
Control method
For 15 schedules,
①
Primary constant-current effective value control
②
Secondary constant-current effective value control
③
Secondary constant-power effective value control
④
Primary constant-current peak value control
⑤
Secondary constant-voltage effective value control
⑥
Constant-phase control
Number of schedules
15