IS-120B
10. Specifications
10-4
①
Overcurrent
100A Fuse
②
No-current
Power is turned off in the following cases:
a.
When a secondary current is not
detected
in secondary constant-current
effective value
control, secondary constant
-power effective
value control or
constant-phase control.
b. When a primary current is not detected
in primary constant-current effective
value control, primary constant-current
peak
value control or secondary constant
-voltage
effective value control.
③
No-voltage
In the s
econdary constant-voltage effective
value control, the supply of the current is
stopped when a secondary voltage cannot
be detected.
④
Temperature
Overheating of power unit of inverter and
welding transformer are detected.
Protective functions
⑤
Self-
diagnostic
error
Setting date such as schedule setting are
diagnosed.