Camera system
messtechnik
EMC Test and Measuring Systems
mk
Extended Manual
i
Not every receiver type has an internal real-time clock, so the commands for setting the time
and date have no function here.
4.3.9 Configuration
The functions on this tab are used to configure internal settings of a receiver. Not every function is supported by
every type of receiver.
4.3.9.1 Device Name
Figure 4-20: Specifying the device name
The name entered in the text field
[1]
can be set with button
[2]
. The device name is then displayed in the title bar
so that you always know which receiver you are currently connected to. Some configuration files may also depend
on the device name (see chapter 4.4.3.2)
4.3.9.2 Front and Remote Control Unit Display
Figure 4-21: Configuring the display texts of the devices display
The texts shown in the display of some receiver and remote control types can be defined via configuration files
(see chapter
4.4.3) and stored in the device using the functions shown here.
Button
[1]
sets the data in the receiver, where it is immediately shown on the display. If one is satisfied with the
display, the texts can be permanently written to the receiver using button
[2]
.
The selection buttons
[3]
are used to decide whether to use the short or long text variant. The smaller black and
white displays can only display the short texts and the larger color displays the long text. However, you can also
use the short texts for the large color display.
!
If a remote control unit with a display is connected to the receiver, the texts are also sent to
this remote control unit. If you want to prevent this, the remote control unit must be
unplugged first!
4.3.9.3 Network Configuration
Some receiver types can optionally be equipped with a network interface (see chapter 3).
In this case, some
Page 30 / 43
Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, www.reliantemc.com