Camera system
messtechnik
EMC Test and Measuring Systems
mk
Extended Manual
Command
Address
Param 1
Param 2
Description
SYS:GRP
250
Group ID
ACSII List
Assigns camera IDs of the ASCII List to the group with the specified ID.
Group ID = The value of the ID must be between 1 and 15.
ASCII List = Each camera ID is listed as a separate character. The ASCII code of the character is
calculated from camera ID + 47. The camera ID must be between 1 and 64.
Omit ASCII List to delete all camera IDs from the selected group.
Example:
SYS:GRP 250 2 0:C assigns camera IDs 1, 11 and 20 to group 2.
Table 5-2: OSD Commands for grouping AV output cards (only receiver type matrix)
5.3.2.3 X-/Y-Position (Parameters 2, 3)
The maximum number of columns (x) and rows (y) on the OSD depends on the output screen resolution and the
font size. Table 5-3 shows the most common combinations.
For other combinations, you use the character widths and heights listed table 5-4 for your own calculation.
Example:
If the horizontal output resolution is 1080 px wide and you set font size "small" (width=12 px), the
maximum OSD row is y = 1080 / 16 = 67.
Output Resolution
Font Size
Maximum
Column (x)
Row (y)
720 x 576 (SD, PAL)
1
60
36
2
30
18
3
22
12
704 x 480 (SD, NTSC)
1
58
30
2
29
15
3
22
10
1280 x 720 (HD)
1
106
45
2
53
22
3
40
15
1920 x 1080 (FHD)
1
160
67
2
80
33
3
60
22
Table 5-3: Maximum x-/y-position by output resolution and font size
5.3.2.4 Font Size and FG-/BG-Colour (Parameters 2, 3)
Font Size
Description
Width
Height
1
Small
12 px
16 px
2
Medium
24 px
32 px
3
Large
32 px
48 px
Table 5-4: Font sizes for transient OSD commands
Page 36 / 43
Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 4089165750, www.reliantemc.com