35
MK-5000G
Block Saws - Pulley Combinations by MK Part Number
Gas Saws (9-13 Hp)
Blade Size
14 inch
20 inch
24 inch
Motor Pulley 9-13 Hp Gas
158470
160365
160365
Jack Shaft Pulley (Motor Side)
160362
160362
160362
Jack Shaft Pulley (Arbor Side)
158959
160364
160364
HD (1")
161135
158470
161135
Motor Belts
160366
Arbor Belts
160367
(F)
Locate Cooling Channels inside
Blade Guard.
Cooling Flow stopped
(A)
Check Cooling Flow
Control Valve is open.
(B)
Remove Transfer Tube from
Blade Guard.
(C)
Place Water Pump in clean
water source and check for flow.
(if no flow go to step G)
“Rodding” cooling channels is performed by removing the flow control valve and then insert-
ing a small wire rod through the cooling channel inlet, located on the underside of the Blade
Guard. The cooling channels should be “rodded” until each of the outlet ports are open and
free of foreign debris.
NOTe:
(D)
Verify Cooling Valve operation
by removing the valve from the
Blade Guard.
(E)
Attach the Cooling Valve to the
Transfer Tube to verify flow –
if no flow, replace valve.
MK-5000G TrOUBLesHOOTiNG