Note:
1. Overload is indicated by the ring indicator flashing once every 3 seconds.
2. The Electronic Dimmer will resume normal operation once the overload is
removed, by switching off and on.
Soft start operation
When the Electronic Dimmer is switched on, light levels gradually reach the
desired level over a period of 1 to 3 seconds, greatly extending life expectancy of
lamps by avoiding initial power surge.
Overload protection
If the Electronic Dimmer is overloaded input to lamp(s) will be reduced (or
switched off if overload is severe) to protect the device and the installation.
Maintenance
Cleaning
Please clean the device with a dry and soft lint free cloth.
Do not use water or any abrasive solvent based or aerosol cleaners as this may
damage, discolor or affect the finish and safety of the appliance.
Features
Power failure recovery
In case of power failure, the dimmer will restore to its previous state upon
power restoration.
Minimum brightness adjustment
The User can adjust the minimum brightness level to suit their environment
and ensure optimum lamp performance. See User Guide for programming
details.
9
10
11
Trailing Edge Dimmers
K34103
GLS/ Tungsten filament,
Mains Tungsten Halogen
25 – 500W
ELV Tungsten Halogen with
Dimmable Electronic Transformer
35 – 500VA
K34104 & K34105
(Per gang)
25 – 300W
35 – 300VA
Dimmable LED Driver
*4-150W
(Max 5 LED drivers only)
*4-120W
(Max 5 LED drivers only)
Neutral connection is mandatory on 1-10V Dimmer. Suitable for use with
dimmable fluorescent or LED lighting which is driven by separate 0/1-10V
control gear.
Suitable for use with 0/1-10V analogue dimmable ballast operating in accordance
with IEC60929 annex E.
Note: This product is only suitable for use with ballasts which are the source of the
control voltage. It is not suitable for any other load type.
1-10V Dimmer
K34499
Rated Load
6AX
Maximum number of ballasts
10
Standard compliances
The products in this range comply with IEC 60669-2-1 and the following EC:
• Low Voltage Directive (73/23/EEC)
• Electromagnetic Compatibility Directive (89/336/EEC)
• Restricted of Hazardous Substances (2011/65/EC)
Warranty
• The Company undertakes to replace or repair, at its discretion, this product
should it become defective within a period of 20 years after delivery (5 years for
mains related electronic products), solely as a result of faulty materials and/or
workmanship. Understandably, if the product has not been installed or
maintained in accordance with the Company’s instructions, has not been used
appropriately, or if any attempt has been made to rectify, dismantle or alter the
product in any way, the warranty will be invalidated. This warranty states the
company’s entire liability. It does not extend to cover consequential loss or
damage or installation costs arising from the defective product. This warranty
does not restrict or infringe the normal statutory rights of the consumer.
• MK Electric wishes to make it clear that it owns all original designs of the
products which it manufactures (whether or not listed in this leaflet) and that it
will take all necessary legal action in any part of the world against any party
found to be manufacturing, distributing, selling or otherwise dealing with any
article which infringes the company’s intellectual property rights in its products,
or any other right of the company therein.
Disposal
Product and packaging should be disposed off via standard refuse facilities at the
end of its useful life. Where ever possible packaging and components should be
recycled.
Technical Help
Tel:
Fax:
mk.technical@honeywell.com
Technical Help
Tel:
Fax:
mk.technical@honeywell.com
+44 (0)1268 563720
+44 (0)1268 563064
+44 (0)1268 563720
+44 (0)1268 563064
Customer Service
Tel:
+44 (0) 1268 563000
Fax:
+44 (0) 1268 563405
Fax:
+44 (0) 1268 563365
(International)
mkorderenquiries@honeywell.com
Customer Service
Tel:
+44 (0) 1268 563000
Fax:
+44 (
0) 1268 563405
Fax:
+44 (0) 1268 563365
(International)
mkorderenquiries@honeywell.com
MK Electric
The Arnold Centre, Paycocke Road,
Basildon, Essex SS14 3EA. UK
www.mkelectric.com
All marks in this document identified with ® or ™
symbol adjacent to the mark are trademarks of MK Electric Ltd.
©Honeywell International Inc.
50081614-001 Rev.A
MK Electric
The Arnold Centre, Paycocke Road,
Basildon, Essex SS14 3EA. UK
www.mkelectric.com
All marks in this document identified with ® or ™
symbol adjacent to the mark are trademarks of MK Electric Ltd.
©Honeywell International Inc.
50081614-001 Rev.A
Load rating & type
Leading Edge Dimmers
K34100
GLS/ Tungsten filament,
Mains Tungsten Halogen
40 - 500W
Mains dimmable LED lamp for
incandescent replacement
6 - 150W
Max.12 lamps
ELV Tungsten Halogen with
dimmable Ferro-magnetic transformer
35 - 400VA
K34101 & K34102
(Per gang)
40 – 300W
6 - 120W
Max. 12 lamps
35 - 240VA
Product specifications
Nominal mains supply voltage
220 to 240V a.c.
Max. acceptable mains fluctuation
198 to 264V a.c.
Mains frequency
50/60Hz ± 3Hz
Ambient temperature range
0°C to 45°C
Other information
Troubleshooting
Unable to fit frontplates to module
Please check if you are fitting the correct frontplate to the correct module. The
frontplate must match the module exactly, e.g. 1 Gang Electronic Dimmer Frontplate
will only fit a 1 Gang Electronic Dimmer Module. Please refer to the instructions for
fitting and removing frontplates on page-3.
Connected Lamp does not turn ON or DIM
Firstly check the lamps have not expired.
Check connections and wiring to the device to ensure it has been
installed correctly.
Check the circuit, by inspecting other devices on the same circuit, to
ensure there is power input to the device.
Ring indicator flashes once every 3 seconds
This is indication of an overload. The Electronic Dimmer will resume normal
operation once the overload is removed, by switching off and on.
If you are facing a problem not listed here, please contact the MK technical team.
(Contact details are listed on the last page)
Notes:
1. Do not use loads of different types on the same circuit.
2. Not suitable for use with any other load type.
3. *Neutral connection is required. It is recommended to connect neutral whenever possible to
extend the load handling capability of the dimmer.
12
13
14
15
(Not applicable to K34499)