background image

®

K5440R 

2 LEVEL REPEATER 
 

Installation & Operating Instructions 

This repeater is used to increase the range between Echo transmitters 
and receivers.  In 

1

-level operation, a radio signal received from a 

transmitter will be passed on to the respective receiver.  In 2-level 
operation a radio signal can be passed over a maximum of two 
repeaters to a receiver!  The repeater is factory preset for 

1

-level 

operation when delivered. 

SAFETY: 

CAUTION!  230V, Danger of electrical shock!

    Always 

disconnect the electricity supply before commencing work on 
the installation. 

The device should be installed by a competent person or a qualified 
electrician in accordance with the device’s installation instructions and 
the appropriate current national wiring regulations. 
It is essential that all connections are made as instructed, that cables are 
not stressed and that terminals are fully tightened. 
Screwless terminals must not have more than one cable inserted into 
each terminal. 
The mains supply to this product must be protected by an appropriate 
fuse or MCB. 

SPECIFICATION: 

 

General Data

 

Transmit frequency

 

868.3MHz 

Power supply

 

230V~ / 50Hz 

Power line protection

 

Circuit breaker rated for 10A max 

Ambient temperature

 

-20 to +40°C 

Test specifications

 

EN 60669-2-1 

Protection type

 

IP20 

RF RANGE: 

The strength of the radio signal between the transmitter and switching 
receiver weakens as distance increases.  The range can be further 
reduced by different materials or interference sources in the propagation 
direction of the radio waves.  The range can be increased by the use of 
Echo Repeaters (radio amplifiers). 

Material

 

Reduction

 

Wood, plaster, non-coated glass 

0 - 10% 

Masonry, wood/plaster walls 

5 - 35% 

Reinforced concrete 

10 - 90% 

Range

 

Conditions

 

> 30 m 

Under good conditions (large, clear space without 
obstructions). 

> 20 m 

Through up to 5 plaster/drywall board walls or 2 
brick/porous concrete walls (furniture and persons in 
the room): 
For transmitter and receiver with good aerial 
positioning/layout. 

> 10 m 

Through up to 5 plaster/drywall board walls or 2 
brick/porous concrete walls (furniture and persons in 
the room): 
For receivers installed in walls or corners of rooms, 
receivers with internal aerial or narrow corridors. 

Through 1-2 

ceilings / walls 

Depending on ceiling/wall armouring and type of 
aerial in the receiver. 

INSTALLATION: 

 

Important:

  This device should be installed into a flush mounted 

installation box. 
It should be installed in an area between the Echo sender and receiver.  
Radio signals received from the sender can then be optimally passed on 
to the receiver. 
•  Install flush-mounted installation box in a suitable position. 
•  Protect power supply cable with a circuit breaker or fuse (max. 10A) 
•  Install the connecting wires. 
•  Insert the device into the flush-mount installation box and screw-

fasten it securely in place.  

•  Affix the blind cover (Art. no.: xx.477.xx) to the device. 

Note:  

NEVER install the repeater in a metal housing or in the immediate 

vicinity of large metal objects.  Installation close to floor level or on the 
floor is not recommended. 

Commissioning 

•  Switch on electric power after installation. 

• 

The repeater is factory preset for 1-level operation when delivered.  
Change the repeater to 2-level operation if this is desired.

 

OPERATION AND FUNCTIONS: 

Manual operation of this device is not possible.  The receiving and 
sending of Echo radio signals is done automatically.

 

1 Level Operation 

In 1-level operation, a radio signal received from a transmitter (LED 
1blinks red) will be passed on to the respective receiver. 

 

 Transmitter 

1-level 

operation 

Receiver 

In 1-level operation, a radio signal received from a transmitter (LED 1 
blinks red) will be passed on to the respective receiver.

 

2 Level Operation 

In 2-level operation (LED 2 blinks red) a sender’s radio signal will be received and 
passed on over a maximum of two repeaters to the respective receiver.

 

 

 Transmitter 

1-level  operation 2-level 

operation  Receiver 

Activating 2-level operation:

 

Press button 2 LEV 
longer than 2s

 

 

LED 2 lights up for about 3s  

(2-level operation is active) 

 
 
 
 
 
 
 

Reviews: