background image

5

937A Multi-Sensor System

Precaución
Consultar los documentos adjuntos
ISO 3864, N.° B.3.1

Precaución
Riesgo de descarga eléctrica
ISO 3864, N.° B.3.6

Precaución
Superficie caliente
IEC 417, N.° 5041

Encendido (alimentación eléctrica)
IEC 417, N.° 5007

Apagado (alimentación eléctrica)
IEC 417, N.° 5008

Puesta a tierra
IEC 417, N.° 5017

Protección a tierra
IEC 417, N.° 5019

Corriente continua
IEC 417, N.° 5031

Corriente alterna
IEC 417, N.° 5032

Corriente continua y alterna
IEC 417, N.° 5033-a

Corriente alterna trifásica
IEC 617-2 N.° 020206

Equipotencialidad
IEC 417, N.° 5021

Caja o chasis
IEC 417, N.° 5020

Equipo de clase II
IEC 417, N.° 5172-a

Vorsicht!
Bitte Begleitdokumente lesen!
ISO 3864, Nr. B.3.1

Vorsicht!
Stromschlaggefahr!
ISO 3864, Nr. B.3.6

Vorsicht!
Heiße Fläche!
IEC 417, Nr. 5041

Ein (Netz)
IEC 417, Nr. 5007

Aus (Netz)
IEC 417, Nr. 5008

Erde
IEC 417, Nr. 5017

Schutzleiter
IEC 417, Nr. 5019

Gleichstrom
IEC 417, Nr. 5031

Wechselstrom
IEC 417, Nr. 5032

Wechselstrom und Gleichstrom
IEC 417, Nr. 5033-a

Drehstrom
IEC 617-2 Nr. 020206

Äquipotentialanschluß
IEC 417, Nr. 5021

Rahmen oder Chassis
IEC 417, Nr. 5020

Geräteklasse II
IEC 417, Nr. 5172-a

Definitionen der am
Gerät angebrachten
Symbole (Deutsch)

|

Símbolos que Aparecen
en la Unidad (Español)

Summary of Contents for HPS 937A Series

Page 1: ...HPSTM Series 937A High Vacuum Multi Sensor System OPERATION AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...August 1998 Part 100009273 Rev 4 0 HPSTM Series 937 A High Vacuum Multi Sensor System...

Page 4: ...k of Alconox Inc Baratron is a registered trademark of MKS Instruments Inc Elgiloy is a registered trademark of Elgiloy Co HPS and IgniTorr are trademarks and I MAG is a registered trademark of MKS In...

Page 5: ...4 Definitionen der am Ger t angebrachten Symbole Deutsch 5 S mbolos que Aparecen en la Unidad Espa ol 5 Safety Precautions 6 Safety Procedures and Precautions English 6 Sicherheitsvorschriften und Vor...

Page 6: ...dard Configuration Codes 40 Setup Review Screen 2 41 Setup Review Screen 3 41 Setup Review Screen 4 42 Setup Review Screen 5 42 Setup Review Screen 6 42 Setup Review Screen 7 43 Pressure Mode 43 Cold...

Page 7: ...IES 937A SENSOR A 1 Cold Cathode Sensors A 1 General A 1 Locating a Cold Cathode Sensor A 1 Orienting a Cold Cathode Sensor A 1 Managing Contamination in a Cold Cathode Sensor A 2 Testing a Cold Catho...

Page 8: ...ng the Baratron Capacitance Manometer A 17 Thermocouple Sensor A 18 General A 18 Orienting the DV 6M Sensor A 18 Connecting the DV 6M Sensor A 18 Cleaning the DV 6M Sensor A 19 APPENDIX B LEAK TESTING...

Page 9: ...f an optional communications module was ordered a separate manual for the module should also be included with the package The Series 937A System s sensors and their connecting cables are sold separate...

Page 10: ...hlight D finition des indications ATTENTION et REMARQUE utilis es dans ce manuel ATTENTION Risque de secousse lectrique ISO 3864 No B 3 6 ATTENTION Se reporter la documentation ISO 3864 No B 3 1 L ind...

Page 11: ...f eine wichtige Mitteilung hin die auf einen Arbeitsablauf eine Arbeitsweise einen Zustand oder eine sonstige Gegebenheit von besondererWichtigkeit aufmerksam macht Definiciones de los mensajes de PRE...

Page 12: ...IEC 417 No 5020 Mat riel de la Classe II IEC 417 No 5172 a Caution refer to accompanying documents ISO 3864 No B 3 1 Caution risk of electric shock ISO 3864 No B 3 6 Caution hot surface IEC 417 No 504...

Page 13: ...IEC 617 2 N 020206 Equipotencialidad IEC 417 N 5021 Caja o chasis IEC 417 N 5020 Equipo de clase II IEC 417 N 5172 a Vorsicht Bitte Begleitdokumente lesen ISO 3864 Nr B 3 1 Vorsicht Stromschlaggefahr...

Page 14: ...onductive parts including knobs and controls that may appear to be insulating can render an electrical shock Do not substitute parts or modify instrument Do not install substitute parts or perform any...

Page 15: ...not remove instrument covers Component replacement and internal adjustments must be made by qualified service personnel only Use the proper power cord Use only a power cord that is in good condition...

Page 16: ...e isol s peuvent tre source d une secousse lectrique Ne pas substituer des pi ces ou modifier l appareil Ne pas utiliser de pi ces d tach es autres que celles vendues par MKS Instruments Inc ou modifi...

Page 17: ...l appareil Le remplacement des composants et les r glages internes doivent tre effectu s uniquement par un personnel d entretien qualifi Utilisation d un cordon d alimentation appropri Utiliser unique...

Page 18: ...ndung zum Schutzleiter verloren besteht an s mtlichen zug nglichenTeilen aus stromleitendem Material die Gefahr eines elektrischen Schlages Dies gilt auch f r Kn pfe und andere Bedienelemente die dem...

Page 19: ...g nur durch qualifizierte Fachleute Das Geh use des Instruments darf vom Bedienpersonal nicht ge ffnet werden Das Auswechseln von Bauteilen und dasVornehmen von internen Einstellungen ist nur von qual...

Page 20: ...la conexi n protectora de puesta a tierra todas las piezas conductoras a las que se tiene acceso incluidos los botones y mandos que pudieran parecer estar aislados podr an producir descargar el ctrica...

Page 21: ...s especializados Los operarios no deben retirar las cubiertas del instrumento El cambio de piezas y los reajustes internos deben efectuarlos nicamente t cnicos especializados Usar el cable el ctrico a...

Page 22: ...Coordination Installation Overvoltage Category II Pollution Degree 2 Power Requirement Nominal 100 120 220 or 230 240 VAC 50 60 Hz MainsVoltage Fluctuations not to exceed 10 of nominal Power Consumpti...

Page 23: ...angle status and error messages Pressure Units Torr mbar Pascal or microns Update Rate 50 msec per sensor or 250 msec per full set of sensors in Pressure and Leak Test modes 100 msec per sensor in al...

Page 24: ...RS 232 and RS 485 2400 4800 9600 19200 bit rate selectable Electronic Casing Aluminum Dimensions 9 x 12 x 3 W x D x H 241 mm x 311 mm x 88 mm Size rack 2U high TypicalWeight 8 0 lb 3 6 kg CE Certific...

Page 25: ...gs DV 6M Pressure Range CC 1 x 10 11 to 1 x 10 2 Torr 1 x 10 11 to 1 x 10 2 mbar 1 x 10 9 to 1 x 10 0 Pa 1 x 10 8 to 1 x 10 1 microns Pirani 5 x 10 4 to 4 x 10 2 Torr 7 x 10 4 to 5 x 10 2 mbar 7 x 10...

Page 26: ...crons CM 1 to 95 of the measurement range of the head e g 1 Torr head is 1 0 x 10 2 to 9 5 x 10 1 Torr 1 3 x 10 0 to 1 2 x 10 2 Pa etc TC 2 0 x 10 3 to 9 5 x 10 1 Torr 2 7 x 10 3 to 1 2 x 10 0 mbar 2...

Page 27: ...lver copper brazing alloy alumina ceramic Elgiloy OFHC copper Series 423 SS 302 SS 304 glass Al Inconel X 750 alumina ceramic Pirani 300 series stainless platinum alumina ceramic silver brazing alloy...

Page 28: ...aximum BakeoutTemperature Without Controller or Cables CC Series 421 250 C 482 F when backshell subassembly removed 125 C 257 F otherwise Series 423 400 C 752 F CF flange version only with magnet remo...

Page 29: ...ange CC 421 2 4 lb 1 1 kg 423 1 8 lb 0 8 kg Pirani 0 5 lb 0 2 kg CEP w KF Flange 0 5 lb 0 2 kg Vacuum Connection CC KF 25 KF 40 2 CF 8 VCR F 1 tubing Pirani CEP KF 16 KF 25 1 8 NPT M with compression...

Page 30: ...22 937A Multi Sensor System Feature and Control Locations Front Panel Rear Panel 11 12 13 14 15 16 17 18 19 20 10 8 9 1 2 3 4 7 6 5...

Page 31: ...le Male 15 pin D Accessory Connector AC Power Inlet IEC 320 Slot for optional Communications Module Analog Module UCAL Enable Disable Switch Female 25 pin D Analog Output Connector Slot CC for Cold Ca...

Page 32: ...ng abnormal pressure and taking appropriate security measures using relay set points Controlling system pressure using the analog output as input to an automatic pressure controller Starting or stoppi...

Page 33: ...f a sensor is turned off not connected properly or used out of range a relevant message replaces its pressure reading The Controller s Function Select rotary switch and push button labels are color co...

Page 34: ...on the Analog Module These include buffered logarithmic and combination logarithmic output Buffered and logarithmic analog outputs are available simultaneously from all sensors A buffered analog sign...

Page 35: ...instrument or any modules To remove a module for modification 1 Using a 1 Phillips screwdriver remove the two screws on the top and bottom of the rear panel of the module 2 Use a small flat blade scr...

Page 36: ...cathode sensor see Analog Module page 31 Setting two jumpers on the cold cathode sensor module can make it compatible with either the Series 937A Controller or older Series 937 or Series 929 controll...

Page 37: ...y verify the setting matches the type of head used Head refers to the full scale pressure reading of the selected sensor This pressure gives a 10V output It is always 1 0 x 10N Torr Heads calibrated s...

Page 38: ...ill display in the unit selected If set points are set prior to a pressure unit change they must be reset Capacitance manometer heads must provide a 0 10V output with full scale range specified in Tor...

Page 39: ...nications Module Optional The character format is 8 data bits MSB always 0 1 stop bit and either even or no parity Select a serial bit rate and protocol from the DIP switch bank SW1 on the RS 232 RS 4...

Page 40: ...ss characters the remaining portion of a faulty command may be misinterpreted Therefore with a parity error the Controller may respond differently from what s expected To avoid this the more robust mu...

Page 41: ...he line voltage requested If you need to change the line voltage set the jumpers for the new voltage and install fuses correspondingly The fuse holders are located adjacent to the voltage selection ju...

Page 42: ...t of the front panel for user notations such as type and location of sensors set point values calibration status or other pertinent information Write with a standard pencil on the labels or apply prep...

Page 43: ...error messages appear on the display after switching on the Series 937A Controller see the Error Messages section on page 64 Mounting the Series 937A controller into a 19 rack HPS Part 100005651 1 At...

Page 44: ...n the Power switch to Off When turning the Controller off allow it to remain off for at least 5 sec before turning it back on If after turning the power on the Controller makes a periodic beeping soun...

Page 45: ...SP3 SP4 or SP5 Set Point Relay Status indicates the corresponding set point relay is active i e pressure is below the set point value TORR mBAR PASCAL or MICRON Unit of Measure indicates selected uni...

Page 46: ...Test mode indicates change due to a probe gas Line segments above or below the center of the bar graph indicate direction and magnitude of the deviation Using the Front Panel Controls The Controller...

Page 47: ...us review screens The sequence and content of setup review screens are shown below Depending on the configuration of the Controller some screens may not appear Setup Review Screen 1 This screen shows...

Page 48: ...perform steps 1 4 before proceeding with the remedies listed in the table Since the resolution of these conditions may involve more than one module it is best to carry out the following steps before a...

Page 49: ...s on the capacitance manometer module have been set to at least one valid head selection Code Condition Remedy CC Module is configured correctly CC 8 Reject Module The high voltage supply of this modu...

Page 50: ...lots CC and A or if the selected control sensor is missing or is unsuitable as a control sensor N O C T L C H no control channel is displayed Setup Review Screen 5 Selected time delay for a cold catho...

Page 51: ...ssure reading when in Pressure mode are listed listed below C T L with CONTROL 1 Slot CC or CONTROL 2 Slot A Control A control sensor is reporting a pressure above the control set point and has turned...

Page 52: ...analog ouput and set point relays continue to work To lock or unlock the front panel controls or to display the lock status 1 Set Function Select switch to Pressure mode and select the bottom display...

Page 53: ...e bar graph and beeper for a new reference pressure At the reference pressure the beeper rate will be less than 1 Hz To leak test your system 1 Pump the system to as low a pressure as possible 2 Turn...

Page 54: ...nd the normally closed contact is closed Reading a Relay Set Point To read the set point value 1 Turn the Function Select switch to Relay Set Points 2 Set the Gauge Select switch to the desired set po...

Page 55: ...ease and depress the Down push button once The set point will decrement to 0 0 5 Press the Up push button to restore the set point and return it to the sensor s range Set points are factory preset to...

Page 56: ...hen either the Function Select or the Gauge Select switch is turned to another position The new set point is not saved if the Controller is turned off before turning one of these switches Setting a Co...

Page 57: ...rotection and Control Set Point Messages Whether a cold cathode sensor or a control sensor is selected bothcontrol and protection set points will be displayed Only the set point selected with the Gaug...

Page 58: ...alibration mode indicating that the calibration can not be changed The UCAL Enable Disable switch does not reset a sensor to its factory calibration It simply allows or prevents changes to existing se...

Page 59: ...layed The bar graph display is activated to indicate the difference between the sensor signal and its present zero calibration value For a capacitance manometer each segment represents 05 of full scal...

Page 60: ...nce manometer signal is read CM ZERO and L O on the capacitance manometer s channel line both appear on the display As soon as any one of the required conditions ceases to be true auto zeroing stops a...

Page 61: ...e new atmospheric value The pressure reading will be displayed as AA for a Pirani and H I for a thermocouple sensor The indicator U will appear next to the display of the channel A considerable atmosp...

Page 62: ...e User Cal push button in step 4 the display will read 7 6x10 2 Torr and the indicator U will appear next to the display of the channel This method assumes the sensor is exposed to 760 Torr of air nit...

Page 63: ...ssure to 760 2 Torr 3 Adjust the potentiometer until the pressure displayed on the front panel is 7 6x10 2 Torr Cold Cathode Operation The cold cathode sensor is turned on and off by switching the hig...

Page 64: ...necessary to press C C Off once before pressing C C On to turn on the sensor Cold Cathode Module Remote Connector The cold cathode sensor may be turned on or off from the rear panel of the Cold Catho...

Page 65: ...thode sensor automatically turns on again The control set point will only turn on the cold cathode sensor as the pressure falls below the set point value if it was first turn off by the control set po...

Page 66: ...mit of the relay set point For a capacitance manometer the lower limit of the control set point is one half of the relay set point lower limit or 0 5 of full scale The upper limit for the control set...

Page 67: ...Rate The A D converter has a conversion time of 50 msec The total pressure update cycle in either Pressure or Leak Test modes is the number of sensors multiplied by 50 msec e g if 5 sensors are operat...

Page 68: ...us sensor conditions Pin 9 provides this function only when a cold cathode sensor is installed in slot A Pin Description 1 analog output combination channel CC 2 analog output buffered channel CC 3 an...

Page 69: ...n to resolve the equivalent of 1 of reading in the logarithmic output If Logarithmic Output Is 0 6 to 9 6 V 0 2 V 9 8 V 10 V 10V 10V 10V 0 V Then Normal range Sensor exposed to a pressure less than in...

Page 70: ...will be 10V The second combination output will be provided on Pin 9 if a cold cathode sensor is in Slot A and it has a valid combination sensor While the cold cathode sensor is disabled the combinati...

Page 71: ...a checksum test If the checksum test finds an error no communications functions are possible Other Controller functions will operate normally With RS 232 communications the data output pin pin 3 of th...

Page 72: ...eter head DIP switch setting was detected see p 29 No recognized modules are plugged into the Controller Push the Up push button to cancel the message The Controller will ignore the incorrectly config...

Page 73: ...Hold right button and press left 4 times to show lock state Hold left button and press right once to change lock state Decrease Setup review screens sequentially Decrease Save new calibration Channel...

Page 74: ...Thermocouple 2 0x10 3 9 5x10 1 Capacitance Manometer 1 0 FS 95 FS 1T 1 0x10 2 9 5x10 1 10 T 1 0x10 1 9 5x10 0 100 T 1 0x10 0 9 5x10 1 1000 T 1 0x10 1 9 5x10 2 10000T 1 0x10 2 9 5x10 3 Control Setpoint...

Page 75: ...0 6 m 100002505 10 ft 3 0 m 100007873 25 ft 7 6 m 100007874 50 ft 15 2 m 100002395 Custom to 300 ft 91 4 m 100008759 Cable for 317 Convection Pirani 345 Pirani Sensor 10 ft 3 0 m 103170006SH 25 ft 7 6...

Page 76: ...r Cold Cathode Series 421 KF 25 104210004 KF 40 104210001 2 CF 104210002 1 tube 104210003 8 VCR F 104210005 Series 423 I MAG KF 25 104230004 KF 40 104230001 2 CF 104230002 1 tube 104230003 Sensor Conv...

Page 77: ...150014 15 mm x 30 mm Tubing 103150016 18 mm x 30 mm Tubing 103150018 Sensor Thermocouple 1 8 NPT M 100006763 HPS Products Series 937A Combination 100009273 Vacuum Sensor System User s Manual Please ca...

Page 78: ...id service is desired if the product is contaminated with potentially corrosive reactive harmful or radioactive materials gases or chemicals When products are used with toxic chemicals or in an atmosp...

Page 79: ...71 937A Multi Sensor System Notes...

Page 80: ...ates the ionization process in cold cathode sensors assuring UHV pressure readings in seconds see Spare Parts and Accessories p 71 Locating a Cold Cathode Sensor Locate a cold cathode sensor where it...

Page 81: ...sensor body Series 423 I MAG Cold Cathode Sensor ConnectingtheI MAGSensor Mount the Sensor to a grounded vacuum system If the I MAG Sensor has a CF flange remove the magnet first to allow clearance fo...

Page 82: ...an using high quality detergents compatible with aluminum such as ALCONOX Scrub with a mild abrasive to remove most contamination Scotch Brite or fine emery cloth may be effective Rinse with alcohol C...

Page 83: ...937A Multi Sensor System A 4 Series 423 I MAG Sensor exploded view 13 15 14 12 11 10 9 8 7 6 5 4 3 1 2...

Page 84: ...has a concave shape Refer to the figures to see its installation orientation 6 Insert the small end of the compression spring into the sensor body 7 Using your thumbs push the larger end of the spring...

Page 85: ...V SHV connector and Ion Current SMA connector Where stress might be applied to the cable use separate strain relief to avoid damage to the sensor cable or the Controller Cables are available from the...

Page 86: ...7 Series 421 Cold Cathode Sensor exploded view of backshell internal and body subassemblies Backshell Subassembly Internal Subassembly Body Subassembly 11 13 14 15 16 17 18 19 20 21 22 23 25 24 26 27...

Page 87: ...generally proceeds from bottom to top of the internal assembly drawing 6 To remove the cathode release the two integral spring loaded ears hooked over the shoulder of the ceramic insulating support 7...

Page 88: ...so remove the backshell subassembly shown on page A 7 Follow steps 1 through 4 of Disassembling the Series 421 Sensor on page A 8 Pirani Sensors General Two types of Pirani sensor can be used with the...

Page 89: ...e the best accuracy can be achieved above 30 Torr by calibrating the sensor oriented vertically with the port facing down The Pirani sensor can be calibrated at any pressure between 600 and 1000 Torr...

Page 90: ...Cables are available in standard lengths of 10 25 50 and 100 feet and in custom lengths up to 500 feet The series 345 Pirani Sensor is connected to the controller using the same cable as the Series 31...

Page 91: ...ct calibration but the tube may still be functional The most common cause of Sensor failure is a broken filament checked from pin 4 to pin 6 due to improper handling Test the Sensor with an ohmmeter w...

Page 92: ...seal Positive pressures might blow the Sensor out of a compression fitting damaging equipment and possibly injuring personnel Do not use a compression mount quick connect to attach the Sensor to a sy...

Page 93: ...he Controller Cables are available from HPSTM in standard lengths of 10 25 50 and 100 feet and in custom lengths up to 500 feet Some applications may require the use of special cables such as where th...

Page 94: ...m the end of the Sensor as shown below 2 Check the resistance on the Sensor s pins listed in the first column on the table below Test the Sensor with an ohmmeter with less than 5 mA of current The res...

Page 95: ...ecommended Any standard vacuum fitting may be used VCR compression KF flange etc The sensor port will easily carry the weight of the transducer Due to the failure of many users to follow the proper ti...

Page 96: ...r Repair by the user is not recommended since replacement or movement of PC board components may require complete calibration of the unit Return to MKS for repair BaratronType 622A shielded cable with...

Page 97: ...NPT do not use the case for tightening The Sensor s vacuum tubing has 9 16 hex flats for tightening Wrap about two turns of Teflon tape on the threads of the Sensor in the direction of the threading t...

Page 98: ...luids condensing or decomposing on the heated filament can contaminate the Sensor This changes the emissivity of the filament which in turn can cause the calibration to change especially at low pressu...

Page 99: ...system For optimal sensitivity select a probe gas with the largest difference between its molecular weight and that of the system gas A gas different than the system gas entering through a leak will...

Page 100: ...If the above leak detection method fails to indicate the location of a leak unexpected high pressures may be caused by a virtual leak i e outgassing of a system component You can locate outgassing pa...

Page 101: ...421 and 423 When using the graphs remember that the pressure scale is always logarithmic and the voltage scale is linear for all sensors except the capacitance manometer Equal increments of distance a...

Page 102: ...937A Multi Sensor System C 2 10 4 10 3 10 2 10 1 100 10 1 10 2 10 3 Pressure Torr 10 8 6 4 2 0 Output Voltage VDC He N2 Ar Buffered Analog Output Pirani Series 315 and 345...

Page 103: ...937A Multi Sensor System C 3 10 3 10 2 10 1 1 10 1 10 2 10 3 10 8 6 4 2 0 Pressure Torr Output Voltage VDC He Ar N2 Buffered Analog Output Convection Pirani Series 317...

Page 104: ...A Multi Sensor System C 4 Buffered Analog Output Capacitance Manometer 10 1 0 1 0 01 Output Voltage VDC 10 3 10 2 10 1 1 10 1 10 2 10 3 10 4 Pressure Torr 1 10 100 1000 10 000 Head Full Scale Range To...

Page 105: ...937A Multi Sensor System C 5 Buffered Analog Output Thermocouple DV 6M 10 9 8 7 6 5 4 3 2 1 0 Output Voltage 10 4 10 3 10 2 10 1 1 10 1 Pressure Torr...

Page 106: ...lti Sensor System C 6 10 4 10 3 10 2 10 1 1 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 10 10 10 11 0 1 2 3 4 5 6 7 8 9 10 N 2 Pressure Torr Output Voltage VDC Logarithmic and Combination Output All...

Page 107: ......

Page 108: ......

Reviews: