background image

INSTALLATION

Note - If this luminaire is being used in conjunction with an external PIR or sensor, please 
confirm with the manufacturer of the sensors that they are compatible with LED lamps
• Provide power to the required point of installation (refer to BS7671 for correct cabling 
   methods)
• Suitable IP rated junction boxes should be used where required
• The luminaire should not be installed in areas where there is a high risk of flooding
• Round cable should be used for the mains supply. The use of flat cable will cause water 
   ingress to the fitting. The luminaire is supplied with an IP68 inline connector allowing the 
   termination of one 3-core flex up to 1.5mm

2

• If fixing into fresh concrete: screw the rods into the fixing plate leaving between 12–16mm 
   of thread above the surface and set it into the wet concrete (see Fig. 1)

Fig. 1

INSTALLATION & MAINTENANCE MANUAL 

 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products: 

OL01B / OL01P 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for 

installation 

 

This product is Class I and must be earthed 

 

This product series is IP54 rated 

INSTALLATION 

Note - If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible with LED lamps

 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods) 

 

Suitable IP rated junction boxes should be used where required 

 

The luminaire should not be installed in areas where there is a high risk of flooding 

 

Round cable should be used for the mains supply. The use of flat cable will cause water ingress to the 

fitting. The luminaire is supplied with an IP68 inline connector allowing the termination of one 3-core 

flex up to 1.5mm2 

 

If fixing into fresh concrete

: screw the rods into the fixing plate leaving between 12

16mm of thread 

above the surface and set it into the wet concrete (see Fig. 1) 

 

 

 

 

Fig. 1 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Knightsbridge OL01B

Page 1: ...INSTALLATION MAINTENANCE MANUAL OL01B OL01P ...

Page 2: ...ition of the IEE Wiring Regulations BS7671 and current Building Regulations If in any doubt consult a qualified electrician Please isolate mains prior to installation or maintenance Check the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this luminaire when de...

Page 3: ...tenance Check the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this luminaire when deciding the location for installation This product is Class I and must be earthed This product series is IP54 rated INSTALLATION Note If this luminaire is being used in conjun...

Page 4: ...pipes or electrical cables Fix the baseplate using suitable fixings not provided Connect the luminaire to the mains supply ensuring the correct polarity is observed Live brown Earth green yellow Neutral blue see Fig 3 Fig 3 Fig 2 Fig 3 If fixing onto solid surface using the baseplate as a template mark the location for and drill the fixing holes ensuring not to infringe with any gas water pipes or...

Page 5: ...amage the product Do not use any source of high pressure washers to maintain or clean this luminaire This product is dimmable dependent on lamp type Tighten the compression gland ensuring a tight seal is made Refit the luminaire to the baseplate and tighten Remove the top of the luminaire by loosening the two Allen screws on the sides and insert a suitable E27 lamp max 20W Switch on and check for ...

Page 6: ... If this product should fail within its warranty period it should be returned to the place of purchase for a free of charge replacement ML Accessories does not accept responsibility for any installation costs associated with the replacement product Your statutory rights are not affected ML Accessories reserve the right to alter product specification without prior notice ML Accessories Limited LU5 ...