LiNX control inputs recognize a number of distinct resistor bands. For each
band, a different action can be selected (e.g. driving, actuator motions,
profile and function navigation and lighting).
Control inputs can be configured to monitor for errors, such as short circuit,
invalid open circuit, missing or unreliable states.
mo-vis has chosen resistor bands 1 and 10: the Twister Pro can perform
monitoring function in these bands, when the dip switch is set to the right
values (see
).
NOTE:
This setting is only accessible with a LiNX Access Key DLX-
HKEY-02.
Chair Set-up
>
Modules
>
Rem XXX
>
Left/Right Jack Socket Tip
>
Advanced
>
Monitored
VALUE
DESCRIPTION
Off
The Twister Pro will function as a normally open switch.
On
The Twister Pro will be able to detect both open- and
short-circuits in the wiring. The error is indicated to the
user and logged in the system.
18
18 Twister Pro Installation manual