NOTE:
Controls
>
External Profile Jack Function
>
Actuator Switches
should be set to
No
for the button to be able to detect open- and short
circuits.
External On/Off Jack Detect
Controls
>
Global
>
External On/Off Jack Detect
VALUE
DESCRIPTION
Off
The Twister Pro will function as a normally open switch.
On
The Twister Pro will be able to detect both open- and
short-circuits in the switch itself or its wiring. If such
conditions are detected, a trip will occur.
Limp
The Twister Pro will be able to detect both open- and
short-circuits in the switch itself or its wiring. If such
conditions are detected, the system will still allow
Drive
but at a reduced speed and will issue a visual and audi-
tive warning.
Dynamic Controls parameters
For more information, please refer to the
GBK54036 LiNX Systems Installation
Manual
.
17
Twister Pro Installation manual 17