Copyright © MOBA Mobile Automation Australia Pty Ltd
12
5.
CHARGING THE LASER
When the Power Indicator light is flashing, the laser must be recharged, or if alkaline batteries are used,
they should be replaced. The charger plugs in to the laser via the plug hole under the laser, shown below.
•
If the indicator light of the charger is red, the batteries are being charged.
•
If the indicator light of the charger is flashing red, the batteries and charger have bad connection.
•
If the indicator light of the charger is green, the charging cycle has ended and the unit is fully charged
Notes:
•
Standard rechargeable batteries will take no more than 7 hours to fully recharge.
•
The power required for the charger is: 85
-
265 V AC 50
-
60HZ (standard mains supply).
•
The instrument can be used while charging.
•
If the laser will be kept in storage or left unused for a long time, the batteries (alkaline or rechargeable
battery) should be taken out.
Alkaline battery
pack
Rechargeable battery
pack
Charging socket