background image

Copyright © MOBA Mobile Automation Australia Pty Ltd

 

 8

 

3.3  SWITCHPAD FUNCTIONS

 

 

All models

 

1.

 

ON/OFF: turns the instrument on and off.

 

2.

 

Power indicator: lights up when the instrument is on and flashes to indicate low battery.

 

3.

 

Automatic/manual mode: switches between automatic and manual modes.

 

4.

 

Mode indicator: when this indicator is on, the instrument is in manual mode. When it flashes the 
instrument is out of self

-

levelling range.

 

5.

 

Height of instrument alert (HI alert): enables the HI alert function. When activated the laser will stop 
rotating if it is jolted or moved. 

 

6.

 

Height of Instrument indicator (HI alert indicator): flashes slowly when HI alert is enabled. When 
flashing rapidly the laser has been jolted or moved and will not self

-

level. 

 

 

All models except LS.RH.HP

 

7.

 

Scanning angle: switches between 5 levels of beam scanning angle: 0, 10°, 45°, 90°, 180°

 

8.

 

Rotating head speed: selects rotating head speed: 0, 60, 120, 300, 600 RPM

 

9.

 

Beam left: moves the laser beam counter

-

clockwise, only when the unit is in 0 RPM or scan mode 

 

10.

 

Beam right: moves the laser beam clockwise, only when the unit is in 0 RPM or scan mode

 

11.

 

X

-

axis: adjusts the slope of the X

-

axis when the instrument is in manual mode.

 

12.

 

Y

-

axis: adjusts the slope of the Y

-

axis, when the instrument is in manual mode.

 

Summary of Contents for ROTEC LS.RH.HP

Page 1: ...USER MANUAL ROTEC LASER LEVEL LS RH HP LS RHV LS RHVG...

Page 2: ...the MOBA Australia service department before warranty repair or replacement can be approved If service in the field is necessary to repair machine mounted equipment under warranty MOBA Australia may a...

Page 3: ...urface checking 14 7 2 Horizontal line checking 15 8 Specifications 16 This manual is an important part of your purchase Please read it thoroughly before using your new equipment We recommend you reco...

Page 4: ...ake sure the instrument is securely fixed The tripod leg clamps should be securely fastened If not securely fastened or tightened the main unit could fall off or the tripod could fall over The laser s...

Page 5: ...to form a plane scanning surface The rotary beam is emitted as illustrated here Horizontal mode all models Vertical mode for vertical and square applications all models except LS RH HP The laser auto...

Page 6: ...Copyright MOBA Mobile Automation Australia Pty Ltd 6 3 PHYSICAL FEATURES 3 1 MAIN BODY HANDLE BATTERY PACK SWITCHPAD ROTATING HEAD LIGHTHOUSE...

Page 7: ...ion Australia Pty Ltd 7 3 2 SWITCHPAD 1 ON OFF switch 2 Power indicator 4 Mode indicator 3 Automatic manual mode 5 HI alert 6 HI alert indicator 7 Scanning angle 8 Rotating head speed 9 Beam left 10 B...

Page 8: ...otating if it is jolted or moved 6 Height of Instrument indicator HI alert indicator flashes slowly when HI alert is enabled When flashing rapidly the laser has been jolted or moved and will not self...

Page 9: ...t 4 2 INSTRUMENT PLACEMENT 4 2 1 HORIZONTAL MODE Set up the instrument on a tripod or lay on a stable flat surface or hang it on a wall using a wall bracket Keep the instrument as flat as possible to...

Page 10: ...nstrument will shut down automatically if the unit exceeds the self levelling range for more than 5 minutes 4 3 3 ROTATING HEAD SPEED OPTIONAL FOR LS RH HP VIA REMOTE CONTROL a Continuous spinning Pre...

Page 11: ...the instrument is set upright for horizontal rotation the slope of the X axis and Y axis can be adjusted by using manual mode To select manual mode press the Automatic Manual Mode switch When the Mode...

Page 12: ...the charger is flashing red the batteries and charger have bad connection If the indicator light of the charger is green the charging cycle has ended and the unit is fully charged Notes Standard recha...

Page 13: ...to 30 meters indoors and 20 meters outdoors The light indicator on the remote will flash to show the operating signal has been sent NOTE the remote is an optional accessory for LS RH HP model Function...

Page 14: ...and begin rotating Mark the beam position on the wall or scale plate as H1 3 Loosen the screw of the tripod and then turn the laser 180 Allow the unit to level and start rotating mark the beam positio...

Page 15: ...l B where the top laser beam strikes the wall 4 Move the tripod and the laser so that it is 0 5 meters away from wall B and 30 meters away from wall A and rotate the laser on its side by 180 degrees s...

Page 16: ...PM 0 60 120 300 600 RPM Laser scanning function 0 10 45 90 180 via optional remote 0 10 45 90 180 0 10 45 90 180 Manual slope adjustment 5 via optional remote 5 5 Remote control operating distance app...

Reviews: