© MOBATIME
35 / 94
801299.00
6.5.13 PTP Configuration
PTP configuration page 1:
DTS 4020.timebridge Moser-Baer AG
====================================
PTP CONFIGURATION config 1 PAGE 1/3
1 Mode 0
2 Profile None
3 Delay mechanism E2E
4 Transport protocol IPv4
5 IPv6 scope 0xE
6 Priority 1 128
7 Priority 2 128
98 Return and save
99 Return and discard changes
Enter desired menu number>
Path: 2 Configuration
2 Time handling
6 PTP settings
1 PTP config
1. Mode
0 = off, 1 = Multicast 1- Step, 2 = Multicast 2 - Step,
3 = Unicast 1-Step, 4 = Unicast 2-Step
2. Profile
0 = none, 1 = default, E2E, 2 = default P2P,
3 = utility(IEC 61850-9-3), 4 = ITU-T G.8265.1,
5 = ITU-T G.8275.1, 6 = ITU-T G.8275.2,
7 = IEEE 802.1AS (gPTP)
3. Delay mechanism
0 = E2E, 1 = P2P, default E2E
4. Transport protocol
0 = IPv4, 1 = IPv6, 2 = layer 2, default IPv4
5. IPv6 scope
1..15, default 15 (0xE)
6. Priority 1
0-255, default 128
7. Priority 2
0-255, default 128
Press ENTER to change to page 2.
PTP configuration page 2:
DTS 4020.timebridge Moser-Baer AG
====================================
PTP CONFIGURATION config 1 PAGE 2/3
8 Domain 0
9 LOG Announce interval 1 (2 second)
10 LOG Sync interval 0 (1 second)
11 LOG Delay Request interval 0 (1 second)
12 Announce TO 3s
13 Sync TO 3s
14 UDP TTL 1
98 Return and save
99 Return and discard changes
Enter desired menu number>
Path: 2 Configuration
2 Time handling
6 PTP function
1 PTP config 1 [Enter]
8. Domain
0-255, default 0
9. LOG Announce interval -7..7, default 1, values in format 2
x
sec (every 2 sec)