A.2
Connections (rear view)
DTS 4132 connections
For technical data, see appendix “H Technical data“.
Clamp
Connection
Description
Earth connection
L
Mains connection phase
Mains power input with rubber connector
Break point: by disconnecting the rubber connector
See Appendix H
Mains connection earth
N
Mains connection neutral
1
DC in 1 power
Input for external DC supply
Ground
2
DC in 1 power supply GND
3
DC in 2 power
Input for external DC supply
Ground
4
DC in 2 power supply GND
5
Alarm relay
Alarm contact, open when alarm is active
Max. load: 30 W (30 VDC or 1A)
or 60 VA (60 VAC or 1A)
6
Alarm relay
7
Alarm input +
Nominal 24 VDC, max. 100 mA
8
Alarm input -
Alarm input: e.g. for external closing contact between
Al and Alarm_in - .
Or voltage input: 18-36 VDC, max. 6mA
Voltage level “high” (24V available) or external contact
closed
configurable: alarm or no alarm.
DTS
extension
DTS extension
DTS extension bus