© MOBATIME
15 / 52
801317.00
Enter a time constant to display the
“time + humidity 2” of the second sensor in
seconds.
Push
PB1S
.The display shows the following:
Enter a time constant to display the
“time + pressure 2” of the second sensor in
seconds.
By pushing the
PB1L
button are the entered values stored and the clock returns
to the menu item
P2
.
3.2.2 Offset setting for time synchronization
Clocks can run with a defined offset to synchronization source.
In menu item
P4
(synchronization source), push
PB1L
to go to the time
synchronization offset setting submenu.
The setting unit is 1/100 second.
Setting range -9.99 to +9.99.
Push
PB1L
to save the setting and return to menu item
P4
.
Push together
PB1L
and
PB2L
to return to
P4
without storage of the data
3.2.3
Submenu for network services configuration
Choose the value
2
or
3
in the item
P19
(network work mode selection) in the
clock menu, then enter the submenu by pushing the
PB1L
pushbutton for
configuring the network services (Multicast support in unicast work mode, SNMP
service, Telnet service). The item to be set is blinking.
The display shows the following:
Switch to the next parameter
– SNMP communication support by pushing the
PB1S
. The display shows the
Sn: 1
. Set value
1
for enabling the SNMP support
or value
0
for disabling it by pushing the
PB2S
.
Switch to the next parameter
– Telnet support by pushing the
PB1S
. The display
shows the
tn: 1
. Set value
1
for enabling the telnet support or value
0
for
disabling it by pushing the
PB2S
.
By pushing
PB1L
save the setting and return to item
P19
.
3.2.4 Manual setting of the IP address of the clock
Choose the item
P20
in the main menu and push the
PB1L
button to enter the
submenu for setting the IP address. The item to be set is blinking.
By pushing
PB2S,
the adjusted digit value is increased in steps of 1, by pushing
the
PB2L
button, the value will be continuously increased.
The display shows the following:
Enter the four octets of the IP address
step by step. Switch to next digit or octet
respectively by pushing the
PB1S
.
Octets are marked by letters
A
,
b
,
C
and
d
.
Set value
1
for enabling the multicast
support in the unicast work mode or value
0
for disabling it by pushing the
PB2S
.
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...