© MOBATIME
34 / 52
801317.00
9.4
Calculation using time zone entries preconfigured by MOBA-NMS
software
P3
A
NTP protocol uses UTC time zone
P4
A
automatic
P6
0
No time zone server is used
P7
U1-U7
Display time and date according to chosen preconfigured time
zone entry, incl. daylight saving time
This setting is suitable for NTP and PoE digital clocks, where several user defined time
zone entries should be used. The time zone entries are preconfigured by means of the
MOBA-NMS software.
9.5
Calculation according to internal time zone table
This setting is suitable for autonomous digital clocks or in cases where the displayed
time is needed in another time zone than provided by the synchronization source.
Displayed time and date calculation is based on the internal time zone table or on the
user
–specific time zone parameters. See the chapter 14 with actual Time zone
definition table.
If you want to use the zone outside the internal time zone table, follow the "Custom
Time Zone settings" appendix
.
P3
0
– 64
According to the time zone in which source of
synchronization works (e.g. value 2 for DCF in
west Europe)
P4
1
– 10,
A
Autonomous operation or any type of the
synchronizing signal
P6
0
Neither MOBALine time zone nor time zone-
server are used
P7
0
– 64,
U
Display time and date by calculation from the
UTC time according to chosen time zone, incl.
daylight saving time
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...