© MOBATIME
36 / 52
801317.00
•
In case of the line fault the clock displays the right time information based
on its own quartz time base. When the normal operation of the line
resumes, the slave clock adjusts itself to the time equal to the master clock.
10.2.2 Synchronization only
– P5 mode 2 and 4
The clock time-base is synchronized by incoming pulses in normal operation of
the slave line.
•
Set current date and time on the slave clocks according the master clock
time with accuracy of ±30 seconds (or ±15 seconds, or ±0,5 second
respectively).
•
The colon flashes in 2 second interval.
•
After 2-3 minutes are the clocks synchronized with the master clock. The
colon is permanently lit during the time display.
•
In case of the line fault the clock displays the right time information based
on its own quartz time base. When the normal operation of the line
resumes, the clock synchronizes with the incoming pulses.
10.3
Slave clock controlled by MOBATIME code, MOBALine, or ActiveDCF
•
After the connection of the digital clock to the signal source, time and date are
adjusted automatically, following the receipt of valid time information.
•
The time setting with using the MOBATIME serial coded line or ActiveDCF takes
place within at least 3 to 4 minutes, for MOBALine within 6 to 15 seconds.
10.4
Slave clock controlled by IF482 over RS485
•
After the connection of the digital clock to the line, time and date are adjusted
automatically, following the receipt of valid time information.
•
Setting the tune takes place within at least 5 minutes.
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...