© MOBATIME
39 / 52
801317.00
multicast config address
239.192.54.1 / FF38::EFC0:3601
(FF38::239.192.54.1)
alive notification interval
[min]
30
configuration port number
65532
time zone client port
number
65534
DHCPv4
enabled
SNMP
enabled
Multicast support
enabled
Telnet
enabled
IPv6 fix address / prefix
0:0:0:0:0:0:0:0/ 64
IPv6 link local address
fe80::2[2. octet MAC]:[3. octet MAC]ff:fe[4. octet
MAC]:[5. octet MAC][6. octet MAC]
DHCPv6
enabled
autoconfiguration (SLAAC)
enabled
11.1.1 Network parameters assignation by DHCP
IP clock mode must be set to IPv4 mode (P18: 0/1).The menu item
P19
must be
set to value
3
(default). Network parameters are automatically obtained from a
DHCPv4 server.
The following DHCP options will be evaluated automatically:
[50] IP address
[3] Gateway address
[1] Subnet mask
[42] list of up to four NTP server addresses / time zone server address (usually
the same as the NTP server address)
[6] DNS servers
[26] MTU
[60] Vendor Class ID
[43] or [224] Additional options (refer to document BE-800793)
The network administrator must configure the DHCPv4 options accordingly.
Assigned parameters can be checked in the submenu of items
P20
to
P22
.
11.1.2 Manual setting through setup menu
The menu item
P19
must be set to value
2
.
•
See chapter 4.2.4 for setting the clock’s IP address in the item
P20
submenu
•
See chapter 4.2.5 for setting the subnet mask in the item
P21
submenu
•
See chapter 4.2.6 for setting the gateway in the item
P22
submenu
•
See chapter 4.2.7 for setting the multicast group address in the item
P23
submenu
•
See chapter 4.2.8 for setting the unicast NTP server address in the item
P24
submenu.
11.1.3 Manual setting through telnet
•
connect to the clock and make the needed settings by windows command
telnet <IP address>
example: telnet 192.168.0.190
•
request for entering the password appears after connection (default
password is 718084)
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...