© MOBATIME
42 / 52
801317.00
12
Testing mode, parameter reset
12.1
Synchronization test
The synchronization signal receive process can be displayed in special testing mode.
This can be useful for example when the problems with the DCF signal receipt appear.
Display description during synchronization test mode:
Two digits on the left side show the current DCF bit number (goes up from 0 to 58).
Third digit shows the type of current DCF bit (0 or 1). The last digit shows the number
of successfully received DCF telegrams. The colon indicates that the DCF bit is
currently received. The dot behind the last digit signalizes synchronized clock.
Entering the synchronization test mode:
•
Enter the clock menu, move to the software version item by several pushes of the
PB1S
or by pushing the
>>
button on IR remote control.
•
Keep pushing both buttons on the clock frame or the
DISP
button on IR
simultaneously until the display shows
C0:00
•
Use the
PB2
or
+
button on IR to set the value behind the colon to
03
•
Keep pushing simultaneously both clock buttons or the
DISP
button on IR, until the
display shows synchronization information
12.2
Parameter reset
If necessary, the clock parameters can be set to factory defaults by the following
procedure.
Activating the parameter reset:
•
Enter the clock menu, move to the software version item by several pushes of the
PB1S
or by pushing the
>>
button on IR remote control.
•
Keep pushing both buttons on the clock frame or the DISP button on IR
simultaneously until the display shows
C0:00
•
Using the
PB2
or
+
button on IR set the value behind the colon to
04
•
Keep pushing simultaneously both buttons or the DISP button on IR, until the
display shows FAC1 and clock makes reset
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...