5.14 AUTHORISATIONS AND REMOTE CONTROL  

By  sending  SMS  commands  remote  control  actions  are  possible,  such  as  arming, 
disarming  and  switching  the  outputs.  As  prerequisite  for  remote  control  the  ‘controlling 
telephone  number’  needs  to  be  authorised.  A  maximum  of  fifty  numbers  can  be 
authorised via SMS command. If it is not clear what memory positions are available, it is 
possible  to  add  a  new  numb

er  by  the  SMS  command  ‘ADDTELA’.  The  new  number 

takes the first free position.  
To receive a list with the authorised numbers, please refer to 8.3. 
SMS-commands  for  remote  control  (no  code  is  necessary,  numbers  need  to  be 
authorised): 
Arm: 

ARM 

Disarm: 

DISARM 

Switch on output 1: 

O1ON 

Switch off output 1: 

O1OFF 

Switch on output 2: 

O2ON 

Switch off output 2: 

O2OFF 

5.15 UNAUTHORISED SWITCHING OF OUTPUTS 

Although  the  Mobeye  MS100E  is  designed  to  only  switch  the  outputs  by  an  incoming 
SMS (or call, see chapter 6) from an authorized phone, there is also an option to let them 
be switched by any incoming call/SMS, without being authorised. To disable the need for 
authorised numbers, the 'authorization' option can be set to OFF. Default is ON. 

5.16 DURATION OF OUTPUTS: SWITCH OR PULSE TIMES 

If  an  output  is  used,  the  time  this  output  is  activated  can  be  set  between  1  and  9999 
seconds.  If  the  setting  is  set  to  0,  the  output  does  not  return  to  its  previous  state 
automatically. An authorised number can switch it back by the SMS command O1OFF or 
O2OFF. In the factory settings the duration of the pulse time for the outputs 

is “10”.  

5.17 INITIAL STATE OUTPUT 

In the factory settings the outputs are set to 

“open” (NO); they close after e.g. the SMS 

command "O1ON". This initial state can be set to 

“closed” (NC). 

5.18 RESET TO FACTORY SETTINGS 

It is possible to reset the Mobeye MS100E to factory settings.  
 

 Remove power adapter (and battery if present) 

 Restore the power source and keep the reset button pressed for 

about 15 seconds  until a short melody sounds followed by 3 
beeps.  

 Release the button when the LED flashes 

 

After  several  seconds  a  short  confirmation  tone  is  heard.  The 
installation code is also reset to 1111. 

Summary of Contents for MS100E

Page 1: ...Installation manual Mobeye MS100E GSM Measure Control and Alarm module SW version 7 n...

Page 2: ......

Page 3: ...rnal use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflammable gases vap...

Page 4: ......

Page 5: ...tomatic time based arm disarm 8 5 8 identification text 9 5 9 Alarm text 9 5 10 Input type 9 5 11 Input delay time 9 5 12 Inactive time 9 5 13 Power failure delay time 9 5 14 Authorisations and remote...

Page 6: ...programmed The SMS message contains the text Mobeye alarm 1 or Mobeye alarm 2 As soon as the inputs leave the alarm status an SMS text message is sent to the set telephone numbers containing the text...

Page 7: ...e a month Open the back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of an external se...

Page 8: ...falls out the unit will keep sits functions and a power failure message can be sent The GSM module remains open and the sensor inputs remain active The back up battery is able to power the module for...

Page 9: ...will send an alarm notification First an SMS text message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm using...

Page 10: ...o an external power source Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100E will send an al...

Page 11: ...Send an SMS message with following content The CODE stands for the installation code Factory setting is 1111 Do not forget the space between CODE and COMMAND The complete scheme with SMS commands is...

Page 12: ...he unit will only send an SMS text message as alarm notification It is not possible to switch off both the SMS and the call 5 5 INTERVAL TEST MESSAGE The Mobeye MS100E can send test messages Through t...

Page 13: ...type is set to NO 5 11 INPUT DELAY TIME The input delay time defines the time that the inputs are triggered before an alarm is initiated If the input returns to the non alarm status within the delay...

Page 14: ...on to let them be switched by any incoming call SMS without being authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 5 16 DURATION OF OUTPUT...

Page 15: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Page 16: ...The unit calls the set alarm numbers The receiver will hear a 2 tone signal and can confirm by pressing 1 6 3 PROGRAMMING ACTION RULES Send following SMS commands in following format CODE TRIGGER REAC...

Page 17: ...be deleted by an SMS by the command below incl index number The index number is the sequence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its...

Page 18: ...ime input 1 DELAY1 0 999 sec 1 Delay time input 2 DELAY2 0 999 sec 1 Power failure delay time DELAYPOW 00 60 min 1 Pulse time output 1 TO1 1 9999 sec 10 Pulse time siren output 2 TO2 1 9999 sec 10 Ini...

Page 19: ...y default restored restored Alarm text input 1 TEXT4 20 characters Alarm 1 Alarm text input 2 TEXT5 20 characters Alarm 2 Text restored input 1 TEXT6 20 characters Input 1 restored 2 Text restored inp...

Page 20: ...ic settings 8 3 AUTHORISATION LIST The list with authorised numbers for remote control can be requested by sending an SMS with the content CODE ANL The originator of the request receives the authorise...

Page 21: ...17...

Page 22: ...red an incorrect installation or user code three times Wait 10 minutes and then re enter the correct installation or user code You do not receive an SMS with the settings Telephone number is not corre...

Page 23: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Page 24: ......

Reviews: