Troubleshooting guide (en) 07/2020 - v.1.1 ©Copyright 2019-2020: Mobile Industrial Robots A/S.
10
Error code
Error type
Description
Solution
650, "Unable to
get version of
LightController
MCU"
Hardware
error.
Can resolve
itself.
See the error above.
650,
"Connecting to
Lightcontroller
MCU failed"
Hardware
error.
Can resolve
itself.
See the error above.
650, "No
firmware
available for
this
Lightcontroller
MCU"
Hardware
error.
Can resolve
itself.
The MiR board is
missing its software.
Reboot the robot. If the problem
persists, and you have not updated to
the latest software, it is recommended
to update your robot. this may solve
the issue.
If the issue occurred after a software
update to the latest version, try to roll
back to a functioning software version
and report the issue to Technical
Support.
If the issue persists, execute a
USB restore. See the guide
How to USB
restore MiR100/MiR200
, found on the
Distributor site.
650,
"Upgrading
firmware
failed"
Hardware
error.
Can resolve
itself.
This error may occur if
the MiR board failed to
update during a
software update.
Try rebooting the robot. You can also
try upgrading the software again.
If the issue persists, execute a
USB restore. See the guide
How to USB
restore MiR100/MiR200
, found on the
Distributor site.